MX60 Current Vs Temperature (all temps Celsius)
Ambient Temperature
25
30
35
40
45
50
55
60
65
70
75
80
Table 1
An easy de-rating rule to use in lieu of the above table is "1 amp per degree C. " Altitude should also
be factored into de-rating. Use the following table to determine altitude-related values.
Altitude Meters/Feet
0 / sea level
1000 / 3,000
1500 / 5,000
2000 / 7,000
3000 / 10,000
3500 /12,000
Table 2
OutBack Power Systems Inc.
Maximum Current (amps)
60.00
57.45
54.77
51.96
48.99
45.83
42.43
38.73
34.64
30.00
24.49
17.32
Factor
1.00
0.95
0.90
0.86
0.80
0.75