STANDARD vs. AUSTRALIAN DEFAULT SETTINGS

The Australian version MX60 has a few default settings that diff er from the Standard version default
settings. However, there are no diff erences in performance and effi ciency between the two ver-
sions. The Standard and Australian version can be identifi ed as follows:
OutBack
Power
MX60
Standard version
Below are a few default setting diff erences between the Standard and Australian version.
Settings
Charger
12 V
24 V
36 V
48 V
60 V
Equalize
12 V
24 V
36 V
48 V
60 V
Equalize Time
OutBack Power Systems Inc.
12V
OutBack
Systems
MX60-AU
Standard
Amps
Absorb
Float
60
14.4 V
13.6 V
60
28.8 V
27.2 V
60
43.2 V
40.8 V
60
57.6 V
54.4 V
60
72.0 V
68.0 V
Equalize Volts
14.4
28.8
43.2
57.6
72.0
01 Hours
12V
Power
Systems
Australian version
Australian
Amps
Absorb
60
14.4 V
60
8.8 V
60
43.2 V
60
57.6 V
60
72.0 V
Equalize Volts
14.7
29.4
44.1
58.8
73.5
03 Hours
Float
13.8 V
27.6 V
41.4 V
55.2 V
69.0 V