Valor 1100IN Danger A Barrier Designed To Reduce The Risk Of Burns From The Hot Viewing Glass Is Provided With Th

H5 series
Hide thumbs Also See for 1100IN:
Table of Contents

Advertisement

DANGER
!
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk
individuals.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
— Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
▪ Do not try to light any appliance.
▪ Do not touch any electrical switch; do
not use any phone in your building.
▪ Leave the building immediately.
▪ Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
▪ If you cannot reach your gas supplier,
call the fi re department.
— Installation and service must be
performed by a qualifi ed installer, service
agency or the gas supplier.
4003682-06
©2016, Miles Industries Ltd.
H5 S
DV ZC Gas Fireplace
1100IN (NG) & 1100IP (LPG)
1150ILN (NG) & 1150ILP (LPG)
Installation & Owner's Manual
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
ERIES
L e a v e t h i s m a n u a l
w i t h t h e a p p l i a n c e .
R e t a i n t h i s m a n u a l
f o r f u t u r e r e f e r e n c e .
Please read this manual
BEFORE installing and
operating this appliance.
This manual contains instructions to install the
ENGINE ONLY. A trim kit is REQUIRED to
complete the installation. A barrier screen is
provided with the trim kit. Refer to the manual
supplied with the trim for installation.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
I N S TA L L E R
C O N S U M E R

Advertisement

Table of Contents
loading

Summary of Contents for Valor 1100IN

  • Page 1 H5 S ERIES DV ZC Gas Fireplace 1100IN (NG) & 1100IP (LPG) 1150ILN (NG) & 1150ILP (LPG) Installation & Owner’s Manual DANGER I N S TA L L E R L e a v e t h i s m a n u a l HOT GLASS WILL w i t h t h e a p p l i a n c e .
  • Page 2: Table Of Contents

    Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2016. All rights reserved.
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully Due to the high temperature, the appliance should be before starting the installation. FAILURE TO FOLLOW LOCATED out of traffi c areas and away from furniture these installation instructions may result in possible fi re and draperies.
  • Page 4: Safety And Your Fireplace

    Child Safety Precautions and Recommendations, A physical barrier is strongly • recommended if there are young Parts of your Valor Fireplace become • extremely hot while in operation. children, or at-risk individuals in the house. Install an approved after- The glass viewing window •...
  • Page 5: Owner's Information

    • READ the SAFETY information on pages be installed by a qualifi ed dealer. Each Valor fi replace 3 and 4 of this manual BEFORE operating is fully tested during the production process for your safety and comfort.
  • Page 6: Cleaning Your Fireplace

    OWNER’S INFORMATION Owner’s Information Cleaning Your Fireplace To remove the window for cleaning: 1. Remove the barrier WARNING screen. Slide the screen DO NOT TOUCH THE GLASS WHILE IT IS HOT! up to disengage the bottom tabs then unhook Let the fi replace cool fi rst before cleaning it. the top tabs.
  • Page 7 fi replace, damage components, cause overheating resulting in dangerous conditions. Damage caused by incorrect window installa- tion is not covered by the Valor warranty. 6. Reinstall the side doors sliding them sideways to insert their tabs behind the front face of the trim.
  • Page 8: Checking Pilot And Burner Flames

    OWNER’S INFORMATION Owner’s Information Barrier screen’s top tabs coming through slots in baffl e/heatshield (behind Trim the face of the trim) Pilot Flame can be seen at the back of the fi re bed Convection baffl e or heatshield 1100 Decorative Glass Murano—Correct Flame Picture 1100 Decorative Glass Set—Correct Flame Picture Ensure the screen is secure and seated all the way down into the bottom slots.
  • Page 9: Using Handset Wall Holder

    OWNER’S INFORMATION Owner’s Information Replacing Batteries Locating Lighting, Operation and Rating Information Card WARNING WARNING DO NOT ATTEMPT TO CHANGE THE BATTER- DO NOT ATTEMPT TO TOUCH THE INFORMA- IES WHILE THE FIREPLACE IS STILL HOT! Let TION CARD WHILE THE FIREPLACE IS STILL the fi...
  • Page 10: How To Turn Your Fireplace Off (Including Pilot)

    OWNER’S INFORMATION Owner’s Information How to Turn Your Fireplace OFF How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently (including pilot) Familiarize yourself with each of the following methods You can use one of the two following methods to before operating your fi...
  • Page 11: Remote Control Operation

    OWNER’S INFORMATION Remote Control Operation NOTE: Before using the remote control system for Signal Indicator the fi rst time, the receiver and the handset must be Time Child Thermostatic Mode Proof paired. See the section Remote Control Initial Pairing Battery on page 61 of this manual.
  • Page 12 OWNER’S INFORMATION Remote Control Operation TO TURN OFF FIRE MANUAL MODE (HANDSET) ) NOTICE Handset Press button and hold for four BEFORE OPERATING seconds to turn OFF. Make sure MANUAL knob on the GV60 Valve is in the ON, full counterclockwise position.
  • Page 13 OWNER’S INFORMATION Remote Control Operation COUNTDOWN TIMER THERMOSTATIC MODE ON/SETTING: Press and hold button until Press button. displayed, preset displayed, and hour flashes. temperature displayed briefly, and then 2. To select hour press button. room temperature displayed. 3. T button. Minutes played.
  • Page 14 OWNER’S INFORMATION Remote Control Operation Default settings: NOTE: PROGRAM 1 and 2 use the same on (Thermostatic) and ON TIME (Thermostatic) TEMPERATURE: 21°C (70°F) off temperatures for and “Daily Timer” ( , , , , OFF TIME TEMPERATURE: “ ” (pilot flame only) , , ).
  • Page 15 OWNER’S INFORMATION Remote Control Operation LOW BATTERY INDICATION Handset alkaline Receiver alkaline AUTOMATIC TURN DOWN 3 Hour No Communication Function Receiver Overheating ° ° ° ° AUTOMATIC SHUT OFF Countdown Timer Low Battery Receiver Five Day Shut Off...
  • Page 16: Options

    Ceramic Liners (choose one)—1100 and 1150 1148CIS Cast Inlay Sheffi eld units 1148CIT Cast Inlay Tatch Conversion Kits—1100 and 1150 units 1110VRL Valor Red Liners 1115LSL Ledgestone Liners 1100PGK From NG to LPG—1100 units only 1125FBL Fluted Black Liners 1100NGK From LPG to NG—1100 units only...
  • Page 17: Lighting Instructions

    OWNER’S INFORMATION Lighting Instructions FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand, remote control, or wall switch. Follow these instructions exactly.
  • Page 18: Commonwealth Of Massachusetts

    QUALIFIED INSTALLER Commonwealth of Massachusetts State of Massachusetts Carbon Monoxide 3. SIGNAGE. A metal or plastic identifi cation plate Detector/Vent Terminal Signage shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above Requirements grade directly in line with the exhaust vent terminal for For all side wall horizontally vented gas fueled...
  • Page 19 QUALIFIED INSTALLER Commonwealth of Massachusetts (d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identifi...
  • Page 20: Specifi Cations

    This appliance must be electrically grounded in Supply Gas accordance with local codes, or, in the absence of local Heater engines 1100IN and 1150ILN are used with codes, with the National Electrical Code, ANSI/NFPA natural gas. 70 or the Canadian Electrical Code, CSA C22.1.
  • Page 21: Overview

    QUALIFIED INSTALLER Overview Mantel—See Mantel & Hearth Clearances Remote Handset Wall Holder Framing—See Framing Requirements i m m arri i er S creen 1/2 inch thick non- (required) combustible board Supplied as Fixed Framing kit or equivalent – vertical outlet, fi eld ( ( 1130FFK) installs at NOT supplied—see convertible to...
  • Page 22: Dimensions & Location

    QUALIFIED INSTALLER Dimensions & Location Dimensions 38” Note: This dimension is for the 1130FFK Fixed Framing Kit. For all 36-1/8” other trims this is the maximum required and may be reduced if positioning the unit forward 25-1/4” of the framing to accomodate thickness of non-combustible Center material over top of...
  • Page 23: Mantel & Hearth Clearances

    QUALIFIED INSTALLER Mantel & Hearth Clearances Combustible Mantel—Left Side View Ceiling Mantel Projection (from Face of Cement Board) 0 2” 1” 4” 6” 8” 10” 12” 49” Mantel 47” Height 45” (from Bottom 43” of Unit) 41” Do not put furniture or objects within 36”...
  • Page 24 QUALIFIED INSTALLER Mantel & Hearth Clearances Combustible Sidewall / Mantel Leg—Top View FIREPLACE Shading denotes Face of allowable location Finished for combustible Wall mantel legs Fireplace Opening 34” 3” Wall Depth 1” 2” 3” 4” 5” 6” or greater Clearance 3”...
  • Page 25: Hearth Requirements

    QUALIFIED INSTALLER Hearth Requirements WARNING SAFETY WARNING! The H5 is a very effective radiant heater. The hearth/fl oor in front of the heater can get very hot (in excess of 200ºF). Locating the unit raised above the hearth/fl oor and using the screen front will greatly reduce hearth temperatures.
  • Page 26 QUALIFIED INSTALLER Hearth Requirements Rules 1. A hearth is not required. However, any hearth/fl oor in front of fi replace within 4 inches vertically of the bottom of the unit must be non-combustible and project a minimum distance as shown on page 27. Hearth/fl oors within 4 inches must have a non-combustible fi...
  • Page 27 QUALIFIED INSTALLER Hearth Requirements Example: If the fi replace is raised 2” above Unit With Site-Built Non-Combustible Hearth Extending combustible fl oor, the non-combustible- fl ush-with-bottom-of-fi replace hearth must project a min. of 6” in front of the fi replace. When using Optional Trims and Front of Fireplace Mantels, Surface of Finished...
  • Page 28: Framing Requirements

    QUALIFIED INSTALLER Framing Requirements Between underside of header and 1/2” thick non-combustible base of heater. Base of heater must board required above engine be at finished hearth height. (not supplied). See page Increase cavity height accordingly. NOTE: This unit requires a solid platform to support it.
  • Page 29 QUALIFIED INSTALLER Framing Requirements Minimum Non-Combustible Board Dimensions Minimum coverage area of non-combustible board. Any wall fi nish applied to shaded area must be non- combustible. We recommend extending the non- combustible board well beyond the size shown to avoid cracking due to differential shrinkage —see page Non-combustible board required...
  • Page 30 QUALIFIED INSTALLER Framing Requirements Framing with Partial Shelf—Top Outlet 13-3/4” (349 mm) Approx. 9-1/4” (235 mm) from back surface of wall finish to front surface of appliance case w/no vent offset 1/2” thick non-combustible board Min. 1” (25.4 mm) clearance to combustibles around vertical...
  • Page 31 QUALIFIED INSTALLER Framing Requirements Venting Considerations—Vertical Takeoff Notes—ALL venting considerations • Dimensions of venting are based on using Dura-Vent elbows. Elbow curve 12” pipe section radius dimensions will vary when using other brands. In general, other brands have slightly bigger radius. •...
  • Page 32: Venting

    QUALIFIED INSTALLER Venting Top or Rear Outlet Framing Vent in Combustible Walls & Ceilings This unit is supplied with a 45 degrees top vent outlet which can be fi eld-converted to a rear vent outlet. See When penetrating through combustible walls and Installation section for more information.
  • Page 33: Co-Axial Venting

    QUALIFIED INSTALLER Co-axial Venting Typical Co-axial Venting Components HORIZONTAL TERMINATION VERTICAL TERMINATION 2-PIECE WALL THIMBLE PIPE STORM LENGTH COLLAR 90˚ ELBOW FLASHING PIPE LENGTH 90˚ ELBOW ATTIC INSULATION SHIELD ATTIC FIRESTOP CEILING FIRESTOP PIPE Rear Vent HORIZONTAL LENGTH TERMINATION 2-PIECE WALL THIMBLE PIPE PIPE...
  • Page 34 QUALIFIED INSTALLER Co-axial Venting How to Read the Venting Chart be used. Excludes the 45 degrees take-off elbow shipped with the appliance. The chart below applies to co-axial roof or wall 6. Each 90 degrees elbow installed on the horizontal termination.
  • Page 35 QUALIFIED INSTALLER Co-axial Venting Restrictors The restrictors are not required when less than 1’-0” vertical rise in vent system. Install the restrictors in the roof of the fi rebox behind the top liner panel. Adjust the restrictors before installation of the top liner panel. Should subsequent adjustment be required, you will need to remove the INSTALL HERE top liner panel—see page 52.
  • Page 36 QUALIFIED INSTALLER Co-axial Venting Horizontal Vent Termination Location or a safety hazard. Local codes or regulations may require greater clearances. • The vent terminal must be located on an outside • The vent terminal must not be recessed into a wall wall or through the roof.
  • Page 37: Co-Linear Venting

    The appliance must not be connected to a chimney fl ue Co-linear serving a separate solid-fuel burning appliance. adapter Requires the Valor Co-Axial to Co-Linear appliance Adapter 1156CLA, two lengths of 2-ply, one 3” and one 3” min. bend radius for intake liner and 4”...
  • Page 38 4” 29” 1-1/2” 4” exhaust collar adapter Dimensions with co-linear adapter Dimensions shown are with Valor 1156 co-linear adapter. Installation 25-1/4” 16-1/4” For installation of the adapter to the appliance, see the instructions supplied with the 1156CLA. Example of co-linear terminal confi gurations...
  • Page 39: Installation Planning

    QUALIFIED INSTALLER Installation Planning Installer—READ THIS FIRST Appliance Height in Framing Only qualifi ed licensed or trained personnel should install this appliance. 1. YOU NEED TO KNOW FROM THE HOMEOWNER: - The height of the unit and hearth if used; - The thickness and type of the wall fi...
  • Page 40: Plan Wall Finish

    QUALIFIED INSTALLER Installation Planning Plan Wall Finish Non-combustible cement board Min. 39-1/2” The H5 fi replace requires a 1/2” (13 mm) thick (1003 mm) non-combustible cement board or equivalent, Gypsum board to be used as a wall surface immediately above up to perimeter of non-combustible board the unit—see diagram for minimum coverage.
  • Page 41 QUALIFIED INSTALLER Installation Planning Cracking If a clean fi nish with no tile, etc. is desired, joints in the non-combustible board and the transition to gypsum board will require special attention if future cracking is to be controlled. Shrinkage and differential movement of the framing and non-combustible wall board can transmit cracking through to tiles, etc.
  • Page 42: Installation

    QUALIFIED INSTALLER Installation Unpack Appliance Convert from Top to Rear Outlet Beware of sharp edges! Wear gloves! (if required) This unit is supplied with a top vent outlet which 1. Remove the cardboard wrapping and the wood can be fi eld-converted to a rear vent outlet. pallet from the appliance and discard.
  • Page 43: Remove Window

    QUALIFIED INSTALLER Installation Remove Window The window is held in place by a spring-loaded lever on each side. Window 1. To remove the window, locate the levers on each frame side of the window towards the top. Using your fi nger, pull the lever towards you and unhook it from the window frame bracket.
  • Page 44: Install Appliance For 1130 Fixed Framing Kit

    QUALIFIED INSTALLER Installation Install Appliance for 1130 Fixed Framing Kit Appliance Depth in Framing—with 1130 Fixed Framing Kit • The 1130 installs to the appliance during the framing stage and the appliance’s position is fi xed in the framing. Wall fi nishes are then applied over top of the fl...
  • Page 45 QUALIFIED INSTALLER Installation Install Appliance with 1130 Fixed Framing Kit Part of the 1130 Fixed Framing Kit installs at the time of Removable panel framing the appliance. Front of The side brackets provided loose with the appliance appliance Lower panel are not needed with this kit.
  • Page 46 QUALIFIED INSTALLER Installation Installation 4. On the appliance, install the side panels as indicated (3 screws per side). 1. Unpack the 1130 kit checking that you have all the pieces on hand. Upper panel RH side panel LH side door RH side Lower panel door...
  • Page 47: Install Appliance For 3 And 4-Sided Trim, Doors Or Cast Mantel

    QUALIFIED INSTALLER Installation Install Appliance for 3 and 4-Sided Trim, Doors or Cast Mantel Appliance Depth in Framing—with 3 and 4-Sided Trims, Doors • The 3 and 4-sided trims are adjustable to accomodate up to an additional 3/4” of tile or other over top of the 1/2”...
  • Page 48 QUALIFIED INSTALLER Installation Install Appliance for 3 or 4-Sided Trims and Hearth considerations Fronts You need to know whether there will be a hearth or not in front of the appliance and some rules must be The 3-sided trims 1135, 4-sided trims 1140, double considered: doors 1149 and cast mantel 1147 are fi...
  • Page 49 QUALIFIED INSTALLER Installation Fit Appliance to Framing 1. Install stud brackets on each side of the appliance (2 screws per bracket). Use the hole or the slot according to the thickness of the wall fi nish—see page 47. 2. Taking great care not to cut your hands on the sheet metal edges, lift the appliance out of its packing base and place it in the framing.
  • Page 50: Install Electrical Wiring (If Necessary)

    QUALIFIED INSTALLER Installation Install Electrical Wiring (if necessary) (for optional fan or power adapter kit) This section provides information to install the electric pre-wiring required for use with the 1195CFK Circulat- ing Fan Kit or GV60PAK Power Adapter Kit. All wiring must be done by a qualifi ed electrician in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/ NFPA 70 or the Canadian Electrical Code, CSA C22.1.
  • Page 51: Connect Gas Supply

    QUALIFIED INSTALLER Installation Connect Gas Supply The gas supply inlet connection is a 3/8” NPT male connector located on / 8 ” 4 - 3 the right hand side of the fi rebox. ( 1 1 The unit is supplied with a stainless steel fl...
  • Page 52: Install Liners

    QUALIFIED INSTALLER Installation Install Liners place the refl ective panel, smooth side visible, in front of the rear ceramic panel, held in place as well The following guidelines apply for all liners. by the bottom rail retainers. 1. Inside the fi rebox, on the top of each side, release the screw of the side panel anchors if necessary so they can rotate freely (one per side).
  • Page 53: Install Driftwood Kit 1101Dwk (1100 Models)

    QUALIFIED INSTALLER Installation Install Driftwood Kit 1101DWK (1100 models) 2. Place the right log on the right side of the ceramic burner inserting the two pegs of the log in the holes Material required of the burner. The rear end of the log rests on the •...
  • Page 54 QUALIFIED INSTALLER Installation 4. Carefully spread shale in the cavity of the ceramic burner. You can also add some shale on the edge outside of the burner plate cavity. NOTE: Ensure the area within the pilot shield is clear of shale pieces. Pebbles Place the pebbles on the platform as shown below.
  • Page 55: Install Decorative Glass Murano 1103Dgm (1100 Models)

    QUALIFIED INSTALLER Installation Install Decorative Glass Murano 1103DGM 3. Carefully spread the glass on top of the burner (1100 models) within the platform opening. Material required • Decorative Glass Murano kit, which contains: • 1 glass platform • 2 platform retainers •...
  • Page 56: Install Decorative Glass Set 1104Dgs (1100 Models)

    QUALIFIED INSTALLER Installation Install Decorative Glass Set 1104DGS 4. Carefully fi ll the metal tray with fi reglass, leveling it (1100 models) with the top of the tray’s fl ange. Material required • Decorative Glass Set, which contains: • 1 metal tray •...
  • Page 57: Install Traditional Logs (1150 Models)

    QUALIFIED INSTALLER Installation Install Traditional Logs (1150 models) Material required • Log set included with the appliance, which contains: • 8 logs • Gloves, if desired Installation Unpack the ceramic logs very carefully to avoid damaging them. Each log has keys to help you locate them on the ceramic burner platform.
  • Page 58 QUALIFIED INSTALLER Installation 3. Place the right-hand middle log locating its notch on 5. Place the center base log locating its notch on the the key in the ember bed as indicated. key in the ember bed as indicated. 4. Place the left-hand base log on the platform locating it on the key as indicated.
  • Page 59 QUALIFIED INSTALLER Installation 7. Place the left-hand cross log locating its notch on the key on the top of the rear log as indicated. Rest the front end of the log on top of the left base log as indicated. 8.
  • Page 60: Refi T And Check Window

    fi replace, damage components, cause overheating resulting in dangerous conditions. Damage caused by incorrect window installa- tion is not covered by the Valor warranty. 3. While you hold it, pull and hook the side levers back to the window brackets on each side.
  • Page 61: Remote Control Initial Pairing

    QUALIFIED INSTALLER Installation Remote Control Initial Pairing The receiver and the handset of the remote control sys- tem must be initially paired before the fi rst use. 1. Insert two 1.5 V AAA alkaline batteries in the handset. 2. Locate the Reset button on the front side of the receiver.
  • Page 62: Check Operation

    QUALIFIED INSTALLER Installation Check Operation 3. Loosen the air shutter screws, adjust and re-tighten. Turn the fi replace fl ame up and down using the remote control to confi rm that the full range of inputs is achieved—see the remote control operation instructions on pages 11–15.
  • Page 63: Install Trim And Barrier Screen

    QUALIFIED INSTALLER Installation Install Trim and Barrier Screen Install the trim chosen by the customer for their fi replace. Install as well the barrier screen which is provided with the trim. Show the customer how to remove the barrier screen to access the controls.
  • Page 64: Wiring Diagram

    QUALIFIED INSTALLER Wiring Diagram MAN-Knob Main Valve Knob Combination Control Valve Interruptor Block terminal Optional Wall Switch Kit 8-Wire Cable 1265WSK Thermocouple Electrode Cable Yellow Connector SPARK SPARK Thermocurrent Interruptor Block Pilot Receiver 4 AA Batteries Battery Compartment Button “RESET: Optional Fan 1195CFK Control...
  • Page 65: Approved Venting Components

    QUALIFIED INSTALLER Approved Venting Components Approved Direct Vent Suppliers for Valor Models 1100, 1150, 1200 , 1400, 1500, 1600 and 1700 Venting Parts Code / availability by Manufacturer Venting Parts Description Standard Co-axial 46DVA-HC 4DT-HC TM-4HT — — 4DHC round...
  • Page 66 fi nishes: a) aluminium; b) black powder coated; c) solid copper. 5. Miles Industries Valor Co-linear adapter 1156CLA cannot be used with models 1200 and 1600. Use only with models 1100, 1150, 1400, 1500 and 1700. 6. Only Miles Industries Valor Co-linear adapter 1156CLA can be used with models 1700.
  • Page 67: Warranty

    The warranty registration card must be completed by the initial owner and returned to the Company within 90 days of purchase. Alternatively, the warranty registration form may be fi lled out online at www.valorfi replaces.com. b) Installation and maintenance must be performed by an authorized and trained dealer in accordance with the Company’s installation instructions.
  • Page 68: Spare Parts

    OWNER’S INFORMATION Spare Parts Part Part Code Description Code Description Number Number Heat shield 4004460 GV60 valve assembly NG 1100 4004498X 45 degrees fl anged elbow 0945JM GV60 valve assembly LPG 1100 4004499X Elbow gasket 4002999 GV60 valve assembly NG 1150 4004500X Top stand-offs (2) 4004469...
  • Page 69 INFORMATION Spare Parts Part Code Description Number Refl ective Glass Liner - 1100 1105RGL Liner panels - complete sets Valor Red Brick Liners 1110VRL Ledgestone Liner Set 1115LSL Fluted Black Liner Set 1125FBL Rear panel Valor Red Brick 4003264 Ledgestone...
  • Page 70 OWNER’S INFORMATION Spare Parts 62 63 64...
  • Page 71 Thank You ... For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only.
  • Page 72 Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

This manual is also suitable for:

1150iln1150ilp1100ip