Checking Pilot And Burner Flames; Replacing Batteries - Valor 1100IN Danger A Barrier Designed To Reduce The Risk Of Burns From The Hot Viewing Glass Is Provided With Th

H5 series
Hide thumbs Also See for 1100IN:
Table of Contents

Advertisement

OWNER'S
INFORMATION
Trim
Convection baffl e or
heatshield
Ensure the screen is secure and seated all the
way down into the bottom slots. There should be
a 1" gap between the top of the barrier screen
and the trim.
b) 1135 Edgemont trims: Hook the top of the
screen to the top of the trim. While hooking the
top hooks, direct the bottom tabs into the slots
of the removable panel at the bottom to lock it in
position. Ensure the screen is secure and seated
all the way down into the bottom slots.
8. Verify that the screen is properly hooked and
secure.

Checking Pilot and Burner Flames

A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
1100 Driftwood Kit—Correct Flame Picture
8
Owner's Information
Barrier screen's top tabs
coming through slots in
baffl e/heatshield (behind
the face of the trim)
Pilot Flame can be seen
under the right rear logs
1100 Decorative Glass Murano—Correct Flame Picture
1100 Decorative Glass Set—Correct Flame Picture
1150 Log Set—Correct Flame Picture
Thermocouple
Probe must be in
Flame
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make
sure that snow, trees, bushes, leaves, or other objects
do not obstruct it.
Examine the vent system and terminal regularly. We
recommend annually.
Using Handset Wall Holder
Your fi replace equipment includes
a wall holder to store the handset.
If it hasn't be installed, refer to the
instructions further on in this manual
for the installation.
Pilot Flame can be seen at
the back of the fi re bed
Pilot Flame can be seen
behind the rear log
Pilot Flame

Advertisement