Valor VENTANA Series Installation Instructions Manual

Gas conversion kit

Advertisement

Available languages

Available languages

Quick Links

This appliance is certifi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Kit Contents
1 Main burner
1 Pilot injector—see chart for identifi cation
1 Main burner elbow injector—see chart for
identifi cation
1 Minimum rate by-pass screw—see chart for
identifi cation
1 Set of conversion labels
1 Ceramic middle log (NG 4001370; LPG 4001534)
Tools Required
Wrenches, to disconnect gas line
Phillips (+) screwdriver, to remove burner module
Small (jewelers size) fl at blade screwdriver, to set
pressure
Small fl at blade screwdriver, to release pressure tap
on valve
Nut driver 8 mm or 5/16", to remove burner nuts
Needle nose pliers, to remove by-pass screw
Hex (Allen) wrench, 4 mm or 5/32", to remove pilot
injector
Manometer, to set pressure when regulator is integral
with valve
Specifi cations
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
4001533-04
© Copyright Miles Industries Ltd., 2014.
V
ENTANA
Gas Conversion Kit
1200PCK/NCK
Use with with Valor Models 1200 Heater ONLY
Installation Instructions
1200NG 1200LPG
Natural
Propane
0-4,500 feet*
36,000
31,000
15,000
15,000
3.6
5.0
11.0
82-1200
92-360
62
190
This conversion kit shall be installed by a
qualifi ed service agency in accordance with
the manufacturer's instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer's
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.
10.5
11.0
14.0
30
125
WARNING

Advertisement

loading

Summary of Contents for Valor VENTANA Series

  • Page 1 ENTANA Gas Conversion Kit 1200PCK/NCK Use with with Valor Models 1200 Heater ONLY Installation Instructions This appliance is certifi ed for use from 0–4500 feet. For WARNING altitudes above 4500 feet, see local codes. This conversion kit shall be installed by a Kit Contents qualifi...
  • Page 2: Conversion Procedure

    General Notes Regarding Conversion The Ventana can be converted before or after installation into a wall. If converting after the fi replace is installed and enclosed into the wall, the access to the minimum rate by-pass screw will require the removal of the burner module. As well, the earlier version of the burner fi...
  • Page 3 Burner Early models—Burner fi xing nuts Later models—Burner fi xing supports accessible from underside of module accessible from the top of module Early models: The burner fi xing points are under the Later models: The burner is fi xed to the burner tray burner module tray and the burner module assembly through two supports.
  • Page 4 Injector Elbow Reinstall the main burner injector elbow—see fi gure Install air shutter on NG units only Re-install 3. Ensure the proper injector for the desired fuel type. log retaining Note the catalogue number from the Specifi cations bracket table on page 1 and the same number stamped on the Thread injector side of the injector elbow.
  • Page 5 Minimum Rate By-Pass Screw Convert the minimum rate by-pass screw accessing the Firebox valve either when the burner is out of the fi rebox or from left side Firebox the bottom hole of the exterior wall of the fi rebox, on the front left hand side of the fi...
  • Page 6: Manifold Pressure

    Manifold Pressure Set the manifold pressure. There are two methods of manifold pressure regulation depending on the fi replace model. Refer to diagrams below to determine appropriate method. Early Models Later Models (with separate regulator) (with integral regulator) Shut-off valve Shut-off valve supplied with supplied with...
  • Page 7 Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Designed and Manufactured by / for Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com...
  • Page 8: Directives D'installation

    LE PREMIER FOYER À GAZ RADIANT Kit de conversion de gaz 1200PCK/NCK Utilisez avec les foyers Valor 1200 SEULEMENT Directives d’installation Cet appareil est homologué pour utilisation de 0 à 4 500 AVERTISSEMENT pieds. Pour altitudes au-dessus de 4 500 pieds, consultez Ce kit de conversion doit être installé...
  • Page 9: Procédure De Conversion

    Le Ventana peut être converti avant son installation dans un mur ou après. Lorsque la conversion est faite une fois le foyer installé dans un mur, le module du brûleur devra être enlevé pour accéder à la vis de taux d’apport minimum.
  • Page 10 Brûleur Production initiale—Écrous de fi xation Production récente—Supports du sous la plaque du brûleur brûleur fi xés sur le dessus Production plus récente : Le brûleur est monté à la Production initiale : Le brûleur se fi xe sur la plaque plaque à...
  • Page 11 Injecteur coude Réinstallez l’injecteur coude au brûleur—voir schéma Installez l’obturateur 3. Assurez-vous que l’injecteur soit approprié au type d’aération sur le Réinstallez brûleur NG seulement de gaz utilisé. Notez le numéro de catalogue indiqué au le support tableau Indices signalétiques à la page 1 et vérifi ez le de bûche même numéro gravé...
  • Page 12 Vis de taux d’apport minimum Côté Changez la vis de taux d’apport minimum en accédant gauche à la soupape lorsque le module du brûleur est hors de de la Devant boîte de la boîte de foyer, ou à travers l’ouverture du bas dans la de la foyer boîte...
  • Page 13 Pression d’admission Réglez la pression d’admission. Il y a deux méthodes pour régler la pression d’admission selon le modèle d’assemblage de soupape. À l’aide des schémas ci-dessous, identifi ez le modèle de soupape. Production initiale Production plus récente (avec régulateur séparé) (avec régulateur intégré) Robinet d’arrêt Robinet d’arrêt...
  • Page 14 Réinstallez les panneaux et bûches de céramique Dessous de la bûche du milieu 1. Réinstallez les panneaux de céramique. Consultez le guide d’installation du foyer. 2. Réinstallez les bûches de céramique utilisant la bûche du milieu appropriée pour le type de gaz—les rainures sous la bûche doivent être alignées avec les orifi...

This manual is also suitable for:

Ventana 1200nckVentana 1200pck