Specifi Cations - Valor 1100IN Danger A Barrier Designed To Reduce The Risk Of Burns From The Hot Viewing Glass Is Provided With Th

H5 series
Hide thumbs Also See for 1100IN:
Table of Contents

Advertisement

QUALIFIED
INSTALLER
Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2014/
CSA 2.33-2014 American National Standard / CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and USA, and to CGA 2.17-91 High Altitude
Standard in Canada. This appliance is for direct vent
installations.
This appliance complies with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only qualifi ed
licensed or trained personnel should install this
appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
20
Specifi cations
*High Altitude Installations
I nput ratings are shown in BTU
per hour and are certifi ed without
deration for elevations up to
4,500 feet (1,370 m) above sea
level.
For elevations above 4,500 feet
(1,370 m) in USA, installations
must be in accordance with the current ANSI Z223.1
and/or local codes having jurisdiction. Heating value
of gas in some areas is reduced to compensate for
elevation—consult your local gas utility to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engines 1100IN and 1150ILN are used with
natural gas.
Heater engines 1100IP and 1150ILP are used with
propane gas.
1100IN
1100IP
The supply pressure must be between the limits shown
in the Ratings section.
Natural
Propane
The supply connection is 3/8" NPT male and located on
0-4,500 feet*
the right hand side of the fi rebox. A shut-off valve (not
28,000
28,000
supplied) is required on the supply line to isolate the
13,000
13,000
unit during service. See Supply Gas Installation section
3.5"
9"
for details.
5"
11"
Conversion Kits
10"
14"
850
300
The 1100 and 1150 are supplied as natural gas or
51
30
propane gas and are fi eld convertible between fuels.
185
125
See instructions packaged with the conversion kits for
further information.
1150ILN 1150ILP
Electrical
Natural
Propane
The 1100 and 1150 are designed to run on battery
0-4,500 feet*
power and do not require an electrical power source to
30,000
30,000
operate as a heater. However, they require electrical
16,000
16,000
power to operate optional 1195CFK Circulating Fan
4"
9"
Kit, 1270RBK Remote Blower Kit or GV60PAK Power
5"
11"
Adapter.
10"
14"
850
360
51
30
195
135
X