Sensing Beam
Visible red Class 1 laser, 655 nm
Supply Voltage (Vcc)
12 to 30 V dc
Power and Current Consumption, exclusive of load
< 675 mW
Sensing Range—Threaded Barrel Models
300 mm models: 25 mm to 300 mm (0.98 in to 11.81 in)
100 mm models: 25 mm (0.98 in) to 100 mm (3.94 in)
Sensing Range—Flush Mount Models
310 mm models: 35 mm to 310 mm (1.38 in to 12.20 in)
110 mm models: 35 mm to 110 mm (1.38 in to 4.33 in)
Analog Output Configuration
0 to 10 V or 4 to 20 mA, depending on model
Output Rating
Analog Voltage Outputs (Q4X..U Models): 2.5 kOhm minimum load
resistance
Analog Current Outputs (Q4X..I Models): 1 kΩ maximum load
resistence at 24 V; maximum load resistance = [(Vcc – 4.5)/0.02 Ω]
Remote Input
Allowable Input Voltage Range: 0 to Vcc
Active Low (internal weak pullup—sinking current): Low State < 2.0
V at 1 mA max.
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Beam Spot Size
Table 1: Beam Spot Size—Long-Range Models
Distance (mm)
Threaded Barrel Models
Flush Mount Models
25
150
300
Table 2: Beam Spot Size—Short-Range Models
Distance (mm)
Threaded Barrel Models
Flush Mount Models
25
50
100
Environmental Rating
IEC IP67 per IEC60529
IEC IP68 per IEC60529
IEC IP69K per DIN40050-9
Shock
MIL-STD-202G, Method 213B, Condition I (100G 6x along X, Y and Z axes,
18 total shocks), with sensor operating
Vibration
MIL-STD-202G, Method 201A (10 Hz to 60 Hz, 0.06 inch (1.52 mm)
double amplitude, 2 hours each along X, Y and Z axes), with sensor
operating
Storage Temperature
–25 °C to +75 °C (−13 °F to +167 °F)
P/N 185623 Rev. D
Size (Horizontal ×
Vertical)
35
2.6 mm × 1.0 mm
160
2.3 mm × 0.9 mm
310
2.0 mm × 0.8 mm
Size (Horizontal ×
Vertical)
35
2.4 mm × 1.0 mm
60
2.2 mm × 0.9 mm
110
1.8 mm × 0.7 mm
www.bannerengineering.com - Tel: +1-763-544-3164
Analog Resolution—Threaded Barrel Models
300 mm models:
25 mm to 100 mm: < 0.3 mm
100 mm to 300 mm: < 1 mm
100 mm models: 25 mm to 100 mm: < 0.15 mm
Analog Resolution—Flush Mount Models
310 mm models:
35 mm to 110 mm: < 0.3 mm
110 mm to 310 mm: < 1 mm
110 mm models: 35 mm to 110 mm: < 0.15 mm
Analog Linearity
Analog linearity performance matches accuracy performance curve
(see
Performance Curves—Threaded Barrel Models
and
Performance Curves—Flush Mount Models
Response Speed
Total response speed varies from 0.5 ms to 2560 ms, depending on
base measurement rate and averaging settings.
See Instruction Manual for more information.
Delay at Power Up
< 750 ms
Ambient Light Immunity
> 5,000 lux
Maximum Torque
Side mounting: 1 N·m (9 in·lbs)
Nose mounting: 20 N·m (177 in·lbs)
Connector
Integral 5-pin M12/Euro-style male quick disconnect (QD)
Construction
Housing: 316 L stainless steel
Lens cover: PMMA acrylic
Lightpipe and display window: polysulfone
Chemical Compatibility
Compatible with commonly used acidic or caustic cleaning and
disinfecting chemicals used in equipment cleaning and sanitation.
ECOLAB
®
certified.
Compatible with typical cutting fluids and lubricating fluids used in
machining centers
Application Note
For optimum performance, allow 10 minutes for the sensor to warm
up
Operating Conditions
35% to 95% relative humidity
Min. Ambient
Temp (°C)
Vcc
All Models
12
24
–10
30
* For 4–20 mA models only: Max. Ambient Sensor Temp (°C) = 50
– (Vcc – 12)/2
on page 8
on page 9).
Max. Ambient Temp (°C)
Q4X...U
Q4X..I
(0–10V)
(4–20 mA)*
50
50
45
40
7

Hide quick links: