NOTE: The input wire function is user-selectable; see the Instruction Manual for details. The default
for the input wire function is off (disabled).
NOTE: Shielded cordsets are recommended for all models with quick disconnect fittings. It is
recommended that the shield wire be connected to -V dc (the blue wire).

Cleaning and Maintenance

Handle the sensor with care during installation and operation. Sensor windows soiled by fingerprints, dust, water, oil, etc.
may create stray light that may degrade the peak performance of the sensor. Blow the window clear using filtered,
compressed air, then clean as necessary using water and a lint-free cloth.

Sensor Programming

Program the sensor using the buttons on the sensor or the remote input (limited programming options).
In addition to programming the sensor, use the remote input to disable the buttons for security, preventing unauthorized
or accidental programming changes. See the Instruction Manual, p/n 185624 for more information.

Setup Mode

1. Access Setup mode and the sensor menu from Run mode by pressing and holding MODE for longer than 2
seconds.
2. Use
and
to navigate through the menu.
3. Press SELECT to select a menu option and access the submenus.
4. Use
and
to navigate through the submenus.
5. Select a submenu option.
Press SELECT to select a submenu option and return to the top menu.
Press and hold SELECT for longer than 2 seconds to select a submenu option and return immediately to
Run mode.
To exit Setup mode and return to Run mode, navigate to
4
and press SELECT.
www.bannerengineering.com - Tel: +1-763-544-3164