Distance Mode; Specifications - Banner K30 Pro Instruction Manual

Optical sensor
Hide thumbs Also See for K30 Pro:
Table of Contents

Advertisement

K30 P
O
S
I
RO
PTICAL
ENSOR
NSTRUCTION
These modes are ideal for applications where more informative indication based on object distance is desired. The sensing range can be used to trigger a discrete
output, and also to vary an animation state to provide another level of feedback about a system.

Distance Mode

Distance Mode sets the device to operate as a gauge, which allows the user to configure a background color and a fill color to display how far an object is within the
Detection Area.
As an object moves along the sensing range, the proportion of fill color to background color changes in a clockwise (CW) or counter-clockwise (CCW) direction. The
proportion of fill color increases as an object approaches the maximum range, and decreases as it moves towards the minimum.
Coarse Distance Mode
Coarse Distance Mode allows the user to divide the Detection Area into custom zones to generate a unique animation when an object is present within that zone
distance.
Configure up to six zones for animation and output state. The minimum zone distance is 50 mm.

Specifications

Supply Voltage (Vcc)
10 V DC to 30 V DC
Supply Current
110 mA maximum current at 30 V DC (exclusive of load)
30 mA typical current at 24 V DC (exclusive of load)
Supply Protection Circuitry
Protected against output short-circuit
Leakage Current Immunity
400 µA
Range
The sensor can detect an object at the following ranges, depending on the
material and size of the target: 20 mm to 1000 mm
Output Ratings
Maximum Load: 150 mA
ON-State Saturation Voltage:
< 2 V DC at 10 mA
< 2.5 V DC at 150 mA
OFF-State Leakage Current: < 10 µA at 30 V DC
Remote Input
Allowable Input Voltage Range: 0 to Vsupply
Active High (internal weak pull-down): High state > (Vsupply - 2.25 V) at 2
mA maximum
Active Low (internal weak pull-up): Low state < 2.25 V at 2 mA maximum
Delay at Power-up
< 1 s
Response Time
Switching frequency: 4 Hz
Discrete output response: 120 ms
Repeatability
5 mm from 20 to 300 mm
8 mm from 300 mm to 600 mm
14 mm from 600 mm to 1000 mm
Temperature Effect
<±5 mm from –20 °C to +50 °C (–4 °F to +122 °F)
Application Note
For the most accurate measurements, allow 5 minutes for the sensor to
warm up
Default Indicator Characteristics
Color
Green
Red
Yellow
Blue
6
M
ANUAL
Dominant Wavelength (nm)or Color
Temperature (CCT)
522
620
576
466
© Banner Engineering Corp. www.bannerengineering.com
Mounting
M22 × 1.5 threaded base, maximum torque 4.5 N·m (40 in·lbf)
Construction
Base, Dome, and Nut: Polycarbonate
Connections
Integral 5-pin or 8-pin M12 male quick-disconnect connector
Models with a quick disconnect require a mating cordset
: A shielded cable is required if the sensor is mounted outdoors or if the cable
NOTE
is longer than 30 m (98.4 ft).
Vibration and Mechanical Shock
All models meet MIL-STD-202F, Method 201A (Vibration: 10 Hz to 60 Hz
maximum, 0.06 inch (1.52 mm) double amplitude, 10G acceleration)
requirements.Method 213B conditions H&I.Shock: 75G with device oper-
ating; 100G for non-operation
Operating Temperature
–20 °C to +50 °C (–4 °F to +122 °F)
Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F)
Sensing Beam
Infrared, 940 nm
Environmental Rating
IP65
Pro Editor Configuration
Connection to Pro Editor software enables control of:
Animation: Steady, Flash, Two Color Flash, 50/50, 50/50 Rotate,
Chase, Intensity Sweep, Color Sweep, Wave, Double Wave
Color: Green, Red, Yellow, Blue, White, Cyan, Magenta, Amber,
Rose, Lime Green, Orange, Sky Blue, Violet, Spring Green
Intensity: Low, Medium, High
Speed: Slow, Standard, Fast
Output State: Normally Open, Normally Closed, Momentary,
Latching, On Delay, Off Delay
Logic Type: Three State Advanced Control (F2 Mode), Seven State
Advanced Control (F2 Mode), Four State Full Logic (Custom)
Pro Converter Cable required to interface between PC and indicator, see
accessories
a
Color Coordinates
x
0.154
0.700
0.689
0.309
0.467
0.463
0.140
0.054
B
E
ANNER
NGINEERING
Lumen Output (Typical at 25
°C)
y
5.8
3.2
7.9
1.3
C
.
ORP

Advertisement

Table of Contents
loading