Specifications - Banner D10 Expert Quick Start Manual

Hide thumbs Also See for D10 Expert:
Table of Contents

Advertisement

D10 Expert™ Discrete Output with Bargraph Display
Sensing Beam
Supply Voltage
Supply Protection Circuitry
Delay at Power Up
Output Configuration
Output Rating
Output Protection
Output Response Time
Repeatability
Adjustments
Indicators
Construction
Environmental Rating
Connections
Operating Conditions
Certifications
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com

Specifications

Standard Sensors
660 nm visible red or 525 nm visible green,
depending on model
10 to 30V dc (10% max. ripple) @ less than 45
mA exclusive of load
Protected against reverse polarity, over voltage, and transient voltages
200 milliseconds max.; outputs do not conduct
during this time
Bipolar; 1 current sourcing (PNP) and 1 current
sinking (NPN)
150 mA max. load @ 25° C (derate 1 mA per °C
increase)
OFF-state leakage current: < 5 µA at 30V dc
ON-state saturation voltage:
NPN: < 200 mV @ 10 mA; 1V @ 150 mA load
PNP: < 1V @ 10 mA; 1.5V @ 150 mA load
Protected against output short-circuit, continuous overload, transient over-voltages, and false pulse on power up
500 microseconds (normal mode) or 200 microseconds (high-speed mode)
100 microseconds (normal mode) or 66 microseconds (high-speed mode)
2 push buttons and remote wire
• Expert-style configuration (Static and Dynamic TEACH, and Window SET)
• Manually adjust (+/–) sensitivity (from push buttons only)
• LO/DO, OFF-delay, and response speed configurable (from push buttons or remote wire)
• Push button lockout (from remote wire only)
Factory Default Settings: Light Operate, Normal Speed, No Delay
8-segment red bargraph: Light-to-dark signal difference relative to taught condition (Window SET)
Sensing contrast (Static or Dynamic TEACH)
Green Status Indicators: LO, DO, High Speed (HS), and OFF-Delay
Green LED: Power ON
Yellow LED: Output conducting
Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover
IEC IP50, NEMA 1
PVC-jacketed 2 m or 9 m (6.5' or 30') 6-wire
integral cable or integral 6-pin Pico-style quick-
disconnect
Temperature: -10° to +55° C (+14° to 131° F)
Storage: -20° to +85° C (-4° to +185° F)
Relative Humidity: 90% @ 55° C (non-condensing)
Models with Bussable Power
660 nm visible red
12 to 30V dc (10% max. ripple) @ less than 45 mA
exclusive of load
850 milliseconds max.; outputs do not conduct during this
time
Main units: Bipolar; 1 current sourcing (PNP) and 1
current sinking (NPN)
Sub-units: 1 current sourcing (PNP) or 1 current sinking
(NPN) output, depending on model
100 mA max. load (derate 1 mA per °C above 30° C)
OFF-state leakage current: < 5 µA at 30V dc
ON-state saturation voltage:
NPN: < 1.5V
PNP: < 2V
Supply 15V or more: up to 16 units with 100 mA outputs
Less than 15V supply (9 m cable):
up to 4 units with 100 mA outputs
up to 8 units with 50 mA outputs
Main units: PVC-jacketed 2 m or 9 m (6.5' or 30')
5-wire integral cable
Sub-units: PVC-jacketed 2 m or 9 m (6.5' or 30')
2-wire integral cable
(CE approval is pending for models with bussable power)

Hide quick links:

Advertisement

Table of Contents
loading