T30RW R-GAGE Washdown Radar Sensor Instruction Manual
Chapter Contents
FCC Part 15 Class A ........................................................................................................................................................................................ 30
Industry Canada Statement for Intentional Radiators ...................................................................................................................................... 30
T30RW Dimensions ......................................................................................................................................................................................... 31
T30RW Beam Patterns .................................................................................................................................................................................... 32
Chapter 6
Range
The sensor can detect an object at the following ranges,
depending on the material of the target:
T30RW-1515 models:
Detection Range: 0.15 m to 15 m (0.5 ft to 49.2 ft)
Measurement Range: 0.2 m to 15 m (0.7 ft to 49.2 ft)
Operating Principle
Frequency modulated continuous-wave (FMCW) radar
Operating Frequency
122 GHz
Frequency Range
T30RW-1515: 122 GHz to 123 GHz
Supply Voltage (Vcc)
Analog Voltage models: 12 V DC to 30 V DC
Analog Current and Dual Discrete models: 10 V DC to 30 V
DC
Use only with a suitable Class 2 power supply (UL) or Limited
Power Supply (CE)
Power and Current Consumption, exclusive of load
Power consumption: < 2.4 W
Current consumption: < 100 mA at 24 V DC
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
(1)
Linearity
T30RW-1515:
<± 20 mm at < 500 mm
<± 4 mm at > 500 mm
Delay at Power-up
< 300 ms
Maximum Torque
2.3 N·m (20 in-lbs)
(2)
Repeatability
< 1 mm
Maximum Output Power
EIRP: 100 mW, 20 dBm
Output Protection
Protected against output short-circuit
Remote Input
Allowable Input Voltage Range: 0 to Vsupply
Active High (internal weak pull-down): High state > (Vsupply -
2.25 V) at 2 mA maximum
Active Low (internal weak pull-up): Low state < 2.25 V at 2 mA
maximum
(1)
Reference target with RCS = 1m².
(2)
Repeatability < 10 mm at Excess Gain < 10×.
June 23, 2023
T30RW Specifications
© Banner Engineering Corp.
Response Time
Analog update rate: 2 ms
Discrete output response: 6 ms
Speeds given for fast mode.
Indicators
Power LED: Green, power on
Signal Strength LED:
Red Flash: weak signal
Red Solid: 4× threshold
Output LEDs: Amber, target within taught analog span/
discrete output status
Construction
Housing: PBT
Barrel Cover: Polypropylene
Output Configuration
Analog Outputs:
·Current models
Discrete Output (Black Wire): IO-Link, push/pull output,
configurable PNP or NPN output
Analog output (White Wire): 4 mA to 20 mA
·Voltage models
Discrete Output (Black Wire): IO-Link, push/pull output,
configurable PNP or NPN output
Analog output (White Wire): Configurable 0 V to 10 V or
0.5 V to 4.5 V
·Dual Discrete models
Discrete Output 1 (Black Wire): IO-Link, push/pull output,
configurable PNP or NPN output
Discrete Output 2 (White Wire): Configurable PNP or NPN,
or Pulse Frequency Modulated (PFM) output
Connections
Integral M12 quick disconnect
Models with a quick disconnect require a mating cordset
Vibration and Mechanical Shock
All models meet MIL-STD-202F, Method 201A (Vibration: 10
Hz to 60 Hz maximum, 0.06 inch (1.52 mm) double amplitude,
10G acceleration) requirements. Method 213B conditions
H&I.Shock: 75G with device operating; 100G for non-
operation
Operating Temperature
–40 °C to +65 °C (–40 °F to +149 °F)
Temperature Effect
< ± 10 mm from –40 °C to +65 °C (–40 °F to +149 °F)
Environmental Rating
IP67 per IEC60529
IEC IP69K per BS/ISO 20653:2013
29