Basic TEACH Instructions

Use the following instructions to teach the Q4X sensor. The instructions provided on the sensor display vary depending on
the type of TEACH mode selected. Two-point TEACH is the default TEACH mode.
1. Press and hold TEACH for longer than 2 seconds to start the selected TEACH mode.
2. Present the target.
3. Press TEACH to teach the target. The target is taught and the sensor waits for the second target, if required by the
selected TEACH mode, or returns to Run mode.
Complete steps 4 and 5 only if required for the selected TEACH mode:
4. Present the second target.
5. Press TEACH to teach the target. The target is taught and the sensor returns to Run mode.

Manual Adjustments

Manually adjust the distance set for the 0 V (4 mA) and 10 V (20 mA) values using the
adjustments vary depending on the TEACH mode selected.

Locking and Unlocking the Sensor Buttons

Use the lock and unlock feature to prevent unauthorized or accidental programming changes. Three settings are available:
—The sensor is unlocked and all settings can be modified (default).
— The sensor is locked and no changes can be made.
—The value associated with 0 V (4 mA) and 10 V (20 mA ) can be changed by teaching or manual
adjustment, but no sensor settings can be changed through the menu.
When in
mode,
(+)(DISP) or (-)(MODE) are pressed, but
When in
mode,
adjust options, briefly press and release (+)(DISP) or (-)(MODE). To enter TEACH mode, press the (SELECT)(TEACH)
button and hold for longer than 2 seconds.
To enter
mode, hold
Holding
and pressing
6
displays when the (SELECT)(TEACH) button is pressed. The analog point displays when
displays if the buttons are pressed and held.
displays when (+)(DISP) or (-)(MODE) are pressed and held. To access the manual
and press
four times. To enter
four times unlocks the sensor from either lock mode and the sensor displays
www.bannerengineering.com - Tel: +1-763-544-3164
Q4X Stainless Steel Analog Laser Sensor
and
buttons. The available
mode, hold
and press
seven times.
.