4 Specifications

4.1 General Specifications

Supply Voltage and Current
18 to 30 V dc (10% maximum ripple); 250 mA maximum at 24 V dc (exclusive of
load)
Supply Protection Circuitry
Protected against reverse polarity and transient over voltages
Delay at Power-up
1.25 seconds
Sensing Beam
670 nm (1 mW) visible red IEC and CDRH Class 2 laser
Measuring Frequency
Dynamically adjusted from 300 to 4000 Hz depending on target conditions, or
locked via LH Series Configurator software.
Output Configuration and Rating
Current output: 4–20mA (current sourcing), maximum load 250 Ω
Output Response Time
User adjustable output filtering via LH Series Configurator software
1.25 ms Analog Output Hold upon loss of target
Vibration and Mechanical Shock
Vibration: IEC60947-5-2, 10-55 Hz, 0.5 mm P-P, 3 axis
Shock: IEC60947-5-2, 30G, 11 milliseconds, half sine wave, 3 axis
Maximum mounting bolt tightening torque: 1 Nm
Factory Default Settings
Measurement Mode: Displacement
Sensor Address: Unset (Address 0)
Baud Rate: 115200
Analog Output: 4-20 mA, positive slope, full scale range

4.2 Performance Specifications

Specification
Measurement Range (mm)
Measurement Span (mm)
Start of Measurement Range (mm)
Reference Distance (mm)
End of Measurement Range (mm)
Maximum Thickness Delta Measurement (mm) 1
Default Ideal Separation for Thickness Delta
Measurement (mm)
Spot Diameter at Reference Distance (micron)
Linearity 2 (0.1% of full scale range) (micron)
Resolution 2, 3 (micron)
1. Thickness Delta is the change in thickness (i.e. 100-110mm is 10mm of thickness delta)
2. Measured at 20°C, using a standard white ceramic target
3. Resolution measured with the Output Filter value set to 64
Construction
Aluminum housing and cover plate; glass lens;
PVC and nickel-plated brass cable
Environmental Rating
IP67
Connections
150 mm (6 in) cable with an 8-pin M12/Euro-style pigtail quick-disconnect;
mating QD cables are purchased separately
Serial Communication Interface
RS-485, optically isolated, up to 230 KBaud
Serial Communication Protocol
LH Network
Application Notes
Allow 30-minute warm-up
Adjustments
None on sensor; Configuration through LH Series Configurator software
Ambient Light
3000 Lux
Temperature Effect
0.01% of full scale range/°C
Operating Conditions
−10 °C to +45 °C (+14 °F to +113 °F)
–10 °C to +80 °C (+14 °F to +176 °F) (storage temperature)
85% maximum relative humidity at +45° C, non-condensing
Certifications
LH30IX485QP
25 to 35
10
25
30
35
10
65
50
10
1
www.bannerengineering.com - Tel: 763.544.3164
L-GAGE
Model
LH80IX485QP
60 to 100
40
60
80
100
40
180
125
40
4
®
LH Series Sensor
LH150IX485QP
100 to 200
100
100
150
200
100
350
225
100
10