Table 8 Global parameters description
Parameter Name
Allows selecting profile switching method. When 'Profile change on
Profile change on
event' is disabled – FM5300 switches profiles depending on GSM
event
operator code method. Otherwise it switches profiles depending on I/O
events (see details in chapter 7.2).
Voice settings
Allows to setup microphone sensitivity and speaker loudness level.
Allows entering one number to which FM5300 will be able to call to.
Call trigger defines input, which will be used to receive or make a call.
Call Settings
Usually to that input a button is connected ("Digital Input 1" is not
allowed, because this input is dedicated for ignition).
Are used to switch between two data sending modes: starting from
newest records or starting from oldest record. Active data link timeout
Record Settings
defines how many seconds should FM5300 keep connection to the
server before disconnecting after successful data transfer. Note that
even if it disconnects from server, it always keep active GPRS session.
Defines maximum input voltage on analog input. Possible cases are: all
Analog input
inputs 0-30V, 0-10V, two inputs 0-10V while other two 0-30V maximum
settings
input range has impact on precision – values on 0-10V input are
measured more precisely than 0-30V (higher resolution).
Defines accelerometer sensitivity range (0.5g, 1g, 1.5, 2g), how many
seconds should movement be detected by accelerometer in order to
Accelerometer
set movement for FM5300 application and how many seconds after
settings
movement is not detected by accelerometer FM5300 application
should treat like movement is still there.
Static Navigation
Allows enabling or disabling functionality.
settings
Figure 22 FM5300 Global parameters