server (129,130), and if driver ID length > 16 and <= 24 then three IO ID's will be sent to server
(129,130,131).
Engine fuel rate:
Amount of fuel consumed by engine per unit of time.
Data Length: 2 bytes
Resolution: 0.05 L/h per bit, 0 offset
Data Range: 0 to 3,212.75 L/h Operational Range: same as data range
Type: Measured
Supporting information:
PGN 65266
Note: Since FW sends this parameter as U32, value after floating point is discarded. Data limit
becomes [0-3,212]. Firmware sends value which is already adjusted with bitgain.
Engine instantaneous fuel economy:
Current fuel economy at current vehicle velocity.
Data Length: 2 bytes
Resolution: 1/512 km/L per bit, 0 offset
Data Range: 0 to 125.5 km/L Operational Range: same as data range
Type: Measured
Supporting information:
PGN 65266
Note: FW sends this parameter as U32, value after floating point is discarded. Data limit becomes
[0-125]. This could have been 1 B IO element, but it is 4 B. Firmware sends value which is already
adjusted with bitgain.
At least one PTO engaged:
Indicates that at least one PTO is engaged
00 No PTO drive is engaged
01 At least one PTO drive is engaged
10 Error
11 Not available
Note: This parameter should only be sent by the controller that has knowledge of all PTO drives
on the vehicle (e.g, the FMS gateway). Individual PTO drive controllers should broadcast this
parameter as "not available".
Data Length: 2 bits
Resolution: 4 states/2 bit, 0 offset
Data Range: 0 to 3 Operational Range: same as data range
Type: Status
Supporting information:
PGN 64932
Note: Firmware captures all values [0x00-0x03].
High resolution engine total fuel used:
Note: Firmware sends value which is already adjusted with bitgain.
111