CHAPTER 2: RS485 INTERFACE (MODBUS RTU)
MM300 MOTOR MANAGEMENT SYSTEM – COMMUNICATIONS GUIDE
Code
Type
0x00C0
0x00C1
0x00C2
0x00C3
0x00C4
0x00C5
0x00C6
0x00C7
0x00C8
0x00C9
0x00CA
0x00CB
0x00CC
0x00CD
0x00CE
0x00CF
0x00D0
0x00D1
0x00D2
0x00D3
0x00D4
0x00D5
0x00D6
0x00D7
0x00D8
0x00D9
0x00DA
0x00DB
0x00DC
0x00DD
0x00DE
0x00DF
0x0400
0x0440
0x0480
0x04C0
0x0502
0x0503
0x0504
0x0505
0x0506
0x0507
0x0508
0x0509
0x050A
0x050B
0x050C
Definition
Virtual Output 1 On
Virtual Output 2 On
Virtual Output 3 On
Virtual Output 4 On
Virtual Output 5 On
Virtual Output 6 On
Virtual Output 7 On
Virtual Output 8 On
Virtual Output 9 On
Virtual Output 10 On
Virtual Output 11 On
Virtual Output 12 On
Virtual Output 13 On
Virtual Output 14 On
Virtual Output 15 On
Virtual Output 16 On
Virtual Output 17 On
Virtual Output 18 On
Virtual Output 19 On
Virtual Output 20 On
Virtual Output 21 On
Virtual Output 22 On
Virtual Output 23 On
Virtual Output 24 On
Virtual Output 25 On
Virtual Output 26 On
Virtual Output 27 On
Virtual Output 28 On
Virtual Output 29 On
Virtual Output 30 On
Virtual Output 31 On
Virtual Output 32 On
End
NOT (1 input)
XOR (2 inputs)
LATCH (2 inputs)
OR (2 inputs)
OR (3 inputs)
OR (4 inputs)
OR (5 inputs)
OR (6 inputs)
OR (7 inputs)
OR (8 inputs)
OR (9 inputs)
OR (10 inputs)
OR (11 inputs)
OR (12 inputs)
FORMAT CODES
2–51

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MM300 and is the answer not in the manual?

Questions and answers

Kristiyan
March 31, 2025

we have a problem with device MM300. it says that the device is invalid through the software and does not read the device. the communication is through RS 485. is it possible to give us an advice or send us some reccomendations or instructions?

1 comments:
Mr. Anderson
March 31, 2025

For a GE MM300 device that is not recognized by software and communicates via RS485, follow these troubleshooting steps:

1. Ensure correct RS485 wiring:
- Use two-wire RS485 in a daisy chain configuration.
- Install a 120 Ohm resistor in series with a 1 nF ceramic capacitor at each end of the link.
- Use shielded wire and ground the shield at only one location.

2. Check device addressing and termination:
- Confirm proper device address and ensure no address conflicts.
- Verify that termination networks are correctly installed at both ends.

3. Confirm half-duplex communication:
- Ensure that the system supports half-duplex communication and not sending and receiving data simultaneously.

4. If using USB for setup (e.g., USB-to-RS485 converter) and the device is not recognized:
- Repeat the connection procedure 2–3 times.
- If still not recognized, uninstall the USB driver from Device Manager under modems.
- Disconnect the USB cable, wait at least 10 seconds, then reconnect.
- When prompted by the Hardware Wizard, select "No, not this time," then "Install the software automatically," and press "Continue Anyway."
- Finish the installation and check if the USB device appears in the setup software.

These steps help ensure proper hardware connection and correct software recognition of the MM300 device.

This answer is automatically generated

Table of Contents

Save PDF