GE MM300 Manual page 56

Motor management system/low voltage motor protection and control
Hide thumbs Also See for MM300:
Table of Contents

Advertisement

FORMAT CODES
2–48
Code
Type
0xC242
0xC282
0xC2C2
0xC302
0xC342
0xC382
0xC3C2
0xC402
0xC442
0xC482
0xC4C2
0xC502
0xC542
0xC582
0xC5C2
0xC602
0xC642
0xC682
0xC6C2
0xC702
0xC742
0xC782
0xC7C2
0xC802
0xC842
0xC882
0xC8C2
0xC902
0xC942
0xC982
0xC9C2
0xCA02
0xCA42
0xCA82
0xCAC2
0xCB02
0xCB42
0xCB82
0xCBC2
0xCC42
0xCC82
0xCCC2
0xCD02
0xCD42
0xCD82
0xCDC2
0xCE02
CHAPTER 2: RS485 INTERFACE (MODBUS RTU)
Definition
Reverse Limit
Starts/Hr Inhibit
Time Between Inhibit
Level 1 Access
Level 2 Access
Level 3 Access
Comms Ctrl Active
Hard Wired Ctrl Active
Field Ctrl Active
MCC Ctrl Active
Process ILock A Stop
Process ILock B Stop
Process ILock C Stop
Process ILock D Stop
Process ILock E Stop
Process ILock F Stop
Process ILock G Stop
Process ILock H Stop
Process ILock I Stop
Process ILock J Stop
HW Stop
Field Stop
MCC Stop
Access Switch Closed
Test Switch Closed
Hard Wired Start A
Hard Wired Start B
Start A
Start B
Field Start A
Field Start B
Contactor A Status
Contactor B Status
Remote Reset Closed
Lockout Reset Closed
UV Restart
Pre-Contactor
MCC Start A
MCC Start B
Comm Start A
Comm Start B
Comm Stop
Fuse Fail Inhibit
Phase Reversal Inhibit
Low Aux Voltage Inhibit
UV Restart Inhibit
Drive Available
MM300 MOTOR MANAGEMENT SYSTEM – COMMUNICATIONS GUIDE

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MM300 and is the answer not in the manual?

Questions and answers

Kristiyan
March 31, 2025

we have a problem with device MM300. it says that the device is invalid through the software and does not read the device. the communication is through RS 485. is it possible to give us an advice or send us some reccomendations or instructions?

1 comments:
Mr. Anderson
March 31, 2025

For a GE MM300 device that is not recognized by software and communicates via RS485, follow these troubleshooting steps:

1. Ensure correct RS485 wiring:
- Use two-wire RS485 in a daisy chain configuration.
- Install a 120 Ohm resistor in series with a 1 nF ceramic capacitor at each end of the link.
- Use shielded wire and ground the shield at only one location.

2. Check device addressing and termination:
- Confirm proper device address and ensure no address conflicts.
- Verify that termination networks are correctly installed at both ends.

3. Confirm half-duplex communication:
- Ensure that the system supports half-duplex communication and not sending and receiving data simultaneously.

4. If using USB for setup (e.g., USB-to-RS485 converter) and the device is not recognized:
- Repeat the connection procedure 2–3 times.
- If still not recognized, uninstall the USB driver from Device Manager under modems.
- Disconnect the USB cable, wait at least 10 seconds, then reconnect.
- When prompted by the Hardware Wizard, select "No, not this time," then "Install the software automatically," and press "Continue Anyway."
- Finish the installation and check if the USB device appears in the setup software.

These steps help ensure proper hardware connection and correct software recognition of the MM300 device.

This answer is automatically generated