3-6 Linux Setup and Operation
Command action
1 List RAID Arrays
2 List Internal Disks
3 Make Mirroring Arrays
4 Repair Mirroring Arrays
5 Delete Mirroring Arrays
6 Remove Disk Partitions
7 Make Striping Array
8 Delete Striping Array
c Configurations
q Quit
Command: 1 (Check if the disk specified is isolated from
the RAID configuration.)
[List RAID Arrays]
Nam
Partition
e
=======================================================
=====
< Mirroring Array (RAID1)>
md0
/boot
md1
swap
md2
/
md3
/var/cras
h
(After verifying the isolation of the specified disk from
the RAID configuration (verifying no partition of the
specified disk is in Member), replace the hard disk. Wait
approximately five minute before the system starts to
resynchronize. If there is no automatic synchronization,
manually restore the disk with the below procedure.)
Command action
1 List RAID Arrays
2 List Internal Disks
3 Make Mirroring Arrays (RAID1)
4 Repair Mirroring Arrays (RAID1)
5 Delete Mirroring Arrays (RAID1)
6 Remove Disk Partitions (RAID1)
7 Make Striping Array
8 Delete Striping Array (RAID1+0)
c Configurations
q Quit
Command: 2 (Check if the replaced disk is recognized by
the system.)
[List Internal Disks]
Slo
Name [use] Information
t
=======================================================
(Label)
Status
( - )
SIMPLEX
( - )
SIMPLEX
( - )
SIMPLEX
( - )
SIMPLEX
(RAID1+0)
(Vendor/Model/Serial)
path
(RAID1)
(RAID1)
(RAID1)
(RAID1)
(RAID1+0)
(RAID1+0)
Member
(1)sda1
(1)sda2
(1)sda3
(1)sda5