2-24 General Description
7.
Upon completion of POST, the password entry screen appears prior to OS startup.
The password entry screen will appear after the normal termination of POST only if
you have set a password in the BIOS setup utility "SETUP."
You can enter a password up to three times. If you enter an incorrect password three
times, the startup will be unsuccessful. In this case, turn off the power and then turn it
on again after waiting 30 seconds to boot the server.
IMPORTANT:
8.
Upon completion of POST, the OS will start up.
Behavior at Occurrence of Error
If POST or OS startup does not finish normally, the server will reboot itself automatically.
At the time of reboot, it will select the other CPU/IO module and run POST or OS startup.
In this manner, the server retries POST or OS startup with different combinations of CPU/IO
modules. If POST does not finish normally with any combinations, the server will stop with the
state of DC OFF or Post end with an error message displayed.
While performing retries, the server displays or registers the error types.
For details of error messages, see Chapter 7 "Troubleshooting."
POST Error Messages
When the server detects an error during POST, it will notify you of the occurrence in the
following manners:
Displays an error message on the display unit.
These notification methods are described in "POST Error Messages" (Page 7-4).
IMPORTANT:
the error messages. They will serve as helpful information at the
time of maintenance.
Set a password after the OS installation.
Before you contact your sales agent, write down