1.3.2
Avoiding Electrostatic Discharge While Working
on the Front of the Server
1. Power off the server.
See
Section 1.2, "Controlling Server Power" on page
2. Perform either Step a or Steps b and c.
a. Attach one end of the antistatic strap to a grounding point on the rack and the
other to your wrist.
b. Remove the server from the rack.
c. Place the server on an antistatic mat or other suitable antistatic surface.
Suitable antistatic surfaces include:
1.4

Opening the Server

The cover of the server is split into two sections, front and back.
The back section hinges to provide access.
The front section detaches to provide access.
The whole cover assembly detaches to provide access to both front and back
sections of the server. This is necessary to replace some components.
Caution – Disconnect the power cord before carrying out this procedure. As long as
the power cord is connected, potentially hazardous energy is present inside the
server.
Caution – After servicing, install and fasten the cover before plugging in the power
cords or turning power on.
Sun electrostatic discharge (ESD) mat, Sun part number 250-1088 (available
through your Sun sales representatives)
The bag or shipping container used to package Sun replacement parts
Disposable ESD mat, shipped with replacement parts or options
1-2.
Chapter 1 Parts Removal and Installation
1-5

Advertisement

Table of Contents
loading