Access Port Issues; Access Ports Are Not Adopted - Symbol WS5000 Troubleshooting Manual

Hide thumbs Also See for WS5000:
Table of Contents

Advertisement

1-6
WS5000 Series Switch Troubleshooting Guide
4. If the switch comes up normally, return the switch to a normal operational readiness state. That is, check
Ethernet NIC 2 IP configuration, adopt access ports and associate an mobile unit.
If the switch continues to go into Diagnostics mode, call Symbol Support or log a Symbol Support Center
call.

1.2 Access Port Issues

This section describes various issues related to access ports within the WS5000 Series Switch network.
Possible issues include:

Access Ports are Not Adopted

1.2.1 Access Ports are Not Adopted
Access ports are not being adopted.
Table 1.7 Access Ports are Not Adopted Troubleshooting Notes
Possible Issue
Suggestions to Correct
Access port is not
configured
Country code for switch is
not set
Access ports are off-
network
Switch is configured as
Standby switch
Access ports are restricted
in configuration
Access Port is on Exclude
List
Miscellaneous other issues
All else...
Table 1.7
provides suggestions to troubleshoot this issue.
Verify that the access port key is entered into the switch prior to setting up any access
ports.
Verify that the country code is entered into the switch prior to adopting any access ports.
The switch is not fully functional until a country code is set.
Use the set countrycode command from the Switch Policy Instance prompt
(
).
WS5000.(Cfg).SPolicy.[Name]>
Verify that the access ports are connected to the network and powered on.
Verify that the switch is not configured as a Standby system prior to adopting any access
ports. Even if a Standby switch is not in use, the Primary switch must be in an "Startup"
state in order for it to adopt access ports.
The state is automatically determined by the failover system. From the CLI, use the show
command from the Standby prompt (WS5000.(Cfg).Standby>). In the returned output
from the command, StandBy mode should be "Primary", and State should be "Startup"
Verify that the switch is not configured with an active switch policy that does not allow
access port adoption. In other words, verify that access port adoption is not set to
"deny".
Verify that the WS5000 Series Switch exclude adoption list does not include the access
ports that are not being adopted.
• To check the list, go to the Switch Policy instance and use the show command
(WS5000.(Cfg).SPolicy.[Name]>).
• To remove an access port from the exclusion list, go to the Switch Policy instance and
invoke the set adoptionlist exclude <MAC_address> remove
(
WS5000.(Cfg).SPolicy.[Name]>
• Check the access port LEDs for "Loadme" message on start-up.
• With a packet sniffer, look for 8375 (broadcast) packets
Contact Symbol Support.
command
)