TCP/IP and Link Settings
56
2. Select Tools - Setup TCP/IP Configuration to display the following Setup
TCP/IP Configuration Dialog Box, and set the TCP/IP Configuration for the
target device. In the following example, the settings are all at their default
values.
3. Enter the IP address to set and press the Get from the Device Button. The
present setting will be obtained. Change the IP address in the New Con-
figuration Box if required.
4. Press the Set to the Device Button. The IP address will be transferred to
the device. The applicable device is the device specified in the Target IP
Address Box. The device must be reset to enable the transferred setting. If
the device is not reset when the new IP address is transferred, click the Re-
set the Device Button.
When the EtherNet/IP Unit is reset, the IP address will be displayed once
in flowing text on the 7-segment display on the front of the Unit.
Note
(1) The transfer function for IP address settings is defined by ODVA specifi-
cations. Target devices that do not support these specifications cannot be
set. When setting the IP address of the target device with the Network
Section 3-8