Setting Tag Data Links
158
The following display will appear when you click the Show Detail Button.
The specified values for detailed parameters will be displayed. Change the
values as required. The connection name cannot be set. They are automati-
cally created using the following rule.
default_N (where N is a 3-digit number (001, 002, etc.) starting from 1)
5. Click the Next Button to switch to the table in the following Wizard Dialog
Box. Follow the instructions to select and input from the list box the input
tag set of the originator device that receives the output tag set of the target
device.
• The blank area in the Input Tag Set Column is the connection that you are
creating.
• The rows in which there are input tag sets are connections that are
already set.
• To prevent duplicate settings, input tag sets that have been used are not
displayed in the list box for input tag sets.
• If there is no applicable input tag set, you can edit a tag set or create a
new one by using the Edit Tag Sets Button and Edit Tag Button.
6. Once the input tag set settings have been completed, click the Finish But-
ton. You can check the set connection by selecting Network - View Devic-
es Connection Structure Tree from the menus.
• The Wizard can be ended even if the input tag set includes a blank row. In
that case, a connection is not created for the blank row.
• You can delete a connection by deleting the input tag sets that were previ-
ously set.
Section 6-2