Omron CJ1W-ETN11 Operation Manual page 232

Sysmac cs/cj series ethernet units
Hide thumbs Also See for CJ1W-ETN11:
Table of Contents

Advertisement

Results Storage Area Response Codes
Response
UNIX error
code
message
0043
EDESTADDRREQ
0044
ENOPROTOOPT
0045
ECONNABORTED
0046
EINPROGRESS
0047
ENOTSOCK
0048
EOPNOTSUPP
0049
EADDRINUSE
004A
ECONNREFUSED
004B
ECONNRESET
004C
EADDRNOTAVAIL
004D
EAFNOSUPPORT
004E
ENETUNREACH
004F
EHOSTDOWN
0050
EWOULDBLOCK
0051
EHOSTUNREACH
0053
ETIMEDOUT
0063
ESELABORT
0066
(None)
0080
(None)
0081
(None)
0082
(None)
Description
Destination address required (desti-
nation address not specified)
Protocol not available (unsupported
option specified)
Software caused connection abort
(another task closed socket)
Operation now in progress (non-
block connection ended during pro-
cessing)
Socket operation on non-socket
Operation not supported on socket
Address already in use (UDP or
TCP open request sent for port
already in use)
Connection refused (TCP socket
(active open) processing refused by
remote node)
Connection reset by peer (TCP
socket closed by remote node)
Can't assign requested address
(mistake in remote IP address)
Address family not supported by
protocol family
Network is unreachable
Host is down
Operation would block
No route to host
Connection timed out (TCP timed
out)
Used for internal Ethernet Unit pro-
cessing
Internal memory cannot be allocated
for processing; the service cannot
be provided.
Timed out for passive TCP open
request
Closed by close command during
socket servicing
Connection with remote node not
achieved for passive TCP open
request
Probable remedy
Close the local socket and try reopening it.
Check the port number.
TCP ports can remain unusable for 1 min after
closing.
Passively open a remote TCP socket, checking
the remote IP address and remote TCP port
number.
Close the local socket and try reconnecting.
Check the setting of the remote IP address and
try reconnecting.
Close the local socket and try reopening it.
Set the path to the remote node in the IP router
table.
Check the remote host and communications
path.
Close the local socket and try reopening it.
The specified node does not exist on the desig-
nated IP network segment. Check the commu-
nications path.
Check the remote host and communications
path.
Close the local socket and try reopening it.
Traffic is too high at the Ethernet Unit. Correct
the user application to reduce traffic at the
Ethernet Unit.
Either the remote node is not executing an
active TCP open or there is a block on the net-
work.
No action is necessarily called for.