System Setup

3-9

System Setup

3-9-1

When Settings are Required

Settings
Broadcast setting
Address conversion method
UDP port number for FINS
Local IP address (CJ Series only)
Subnet mask
FTP login name
FTP password
IP address table
IP router table
Mail function
3-9-2

Using a Programming Device

3-9-3

CPU Bus Unit System Setup Defaults

The settings for the Ethernet Unit's basic and special functions are made in
the CPU Bus Unit System Setup. These settings, and the situations in which
the settings must be made, are shown in the following table. For details on
how to make the settings, refer to 4-2 CPU Bus Unit System Setup.
When Ethernet is used with UNIX 4.2BSD specifications.
• When the FINS communications service is used on an Ethernet network.
• When it is necessary to set a value outside of the range of 1 to 126 for the least sig-
nificant byte of the local IP address.
When it is necessary to set a value other than the default (9600) for the FINS UDP
port number.
When setting the local IP address with the CPU Bus Unit System Setup (i.e., when
not setting the local IP address with the allocated words in the DM Area).
When it is necessary to set a subnet mask.
When setting the login name and password at the FTP server.
• When the FINS communications service is used on an Ethernet network.
• When it is necessary to set a value outside of the range of 1 to 126 for the least sig-
nificant byte of the local IP address.
• When the Ethernet network is configured with multiple segments.
When the mail function is used.
Refer to 4-2 CPU Bus Unit System Setup for details.
The settings for the CPU Bus Unit System Setup must be made using the Unit
settings on a CX-Programmer connected to the PC. The settings cannot be
made using a Programming Console. For details on how to connect and use a
CX-Programmer, refer to the CX-Programmer User's Manual.
The following table shows the items in the CPU Bus Unit System Setup, and
their default settings.
Item
Broadcast settings
Address conversion method
UDP port number for FINS
Local IP address (CJ Series only)
Subnet mask
FTP login name
FTP password
IP address table
IP router table
Mail settings
User-created mail data address
Local mail address
When settings are required
All 1 (4.3BSD specifications)
Automatic address generation
9600
0.0.0.0 (The local IP address is set with
allocated words in the DM Area.)
0.0.0.0 (A value corresponding to the IP
address is used.)
CONFIDENTIAL
Not set.
Not set.
Not set.
None set.
Not set.
Not set.
Section 3-9
Default
51