Upload Troubleshooting

This subsection provides information for troubleshooting upload problems.
Problem
Not all fixtures on
link are receiving
download
Status Cue displays:
Fixture could not
erase flashrom
Status Cue displays:
WARNING: No
response from Fix-
ture xx (Link xx
Address xx)
Fixture displays
b O O T d I F F
Fixtures are not
cross-loading
Table A.3: Upload Troubleshooting
Probable Cause
unit(s) turned off
bad cable(s)
cable(s) disconnected
the XLR cable(s) was
disconnected
bad cable(s)
the fixture's electrical
circuitry is damaged
Status Cue was con-
figured with a Studio
Color at that address
but no fixtures were
found there
fixture(s) using RS-
422 is physically con-
nected before Studio
Color fixtures
new software also
included boot code
(normal)
a controller is
connected to the link
fixture(s) using RS-
422 is physically
connected before Stu-
dio Color fixtures
Solution
turn on unit(s)
test and replace cable(s) as
necessary
reconnect cable(s)
reconnect XLR cable(s)
replace cable(s)
refer to qualified service
personnel
if there is not a fixture at that
address, nothing is wrong
check connections
check to ensure fixture is
turned on
remove the fixture(s) from the
data link or move them after
Studio Color fixtures
refer to "Changing Boot
Codes" on page 3-12
disconnect the controller and
attempt the upload again
remove the fixture(s) from the
data link or move them after
Studio Color fixtures
Appendix A Troubleshooting and Maintenance
A-9