2.3 Power Supply Troubleshooting
SPURS-P5V / P5 output
Error code
E0h
E1h
E2h
Miscellaneous
Error code
F0h
Check 2
In the case of error code 10h or 12h:
Check 3
In the case of error code 21h:
Check 4
For any other errors, go to Procedure 5.
QOSMIO G50 Maintenance Manual (960-683)
Downloaded from LpManual.com Manuals
Meaning
SPURS-P5V / P5 voltage is over 6.00V.
SPURS-P5V / P5 voltage is under 4.50V when the computer is powered on.
SPURS-P5V / P5 voltage is under 4.50V when the computer is booting up.
Meaning
The sub clock does not oscillate.
Make sure the AC adapter and AC power cord are firmly plugged into the DC
IN 15 V socket and wall outlet. If the cables are connected firmly, go to the
following step.
Connect a new AC adapter and AC power cord. If the problem still occurs, go
to Procedure 5.
Go to Procedure 3.