3.6.6.2 MFIM Upgrade
First, confirm previous version of MFIM, then upload the desired ROM files and reset system. If the
new system database is not compatible with existing system database, it will be necessary to
initialize the system database. This can be done manually using the Initialize Dip-switch located
on the MFIM, refer to section 1, or using the Initialization process of section 1.3. Upgrade of the
MFIM includes HTML files, a separate upload of the HTML files is not required.
3.6.6.3 Upgrade HTML Files
The system's html files in "File View" Menu, upload file and reload page. Upload time of html will
take 5 ~ 10 minutes.
3.6.6.4 Appliances Upgrade (gateway Module and iPECS Phone)
Upload appliance image, and click "Upgrade process" to select upgrade appliances. If appliances
are selected, click "Upgrade". The page shown in Figure 3.6.3-1 will be displayed indicating the
Upload command has been sent and upgrade process is working. This page will display the
Upload status.
When the appliance upgrade process is successful, the status is updated to
"Success". If the upgrade process fails, the process is attempted an additional three (3) times
before abandoned.
3.6.6.5 Direct Appliances Upgrade
Should the above MFIM managed upgrade process fail, appliances (gateway Modules and iPECS
Phones) can be upgraded directly using the appliance IP address as the upgrade destination
address. Note the later may require local access.