Rsgm Music Assignment -Pgm Code 434- - LG-Nortel iPECS-50 Administrator And Maintenance Manual

Table of Contents

Advertisement

IPECS
Release 5
Admin & Maintenance
2
001-001 CONTACT TYPE
(1:CLOSE/0:OPEN) : CLOSE
3
001-001 ALARM/DOORBELL
(1:ALARM/0:BELL) : ALARM
4
001-001 SIGNAL MODE
(1:RPT/0:ONCE) : RPT

2.3.12.5 RSGM Music Assignment -PGM Code 434-

The RSGM provides Background Music (BGM) to the local iPECS Phone. It also provides MOH to
the local CO Line when placed on hold. BGM is provided from the assigned 'Music' source, which
may be internal or an external source may be connected. MOH may use the assigned 'Music'
source or an internal "hold tone".
PROCEDURE:
RSGM MUSIC ASSIGN
ENTER RANGE(001 – 035)
001-001 MUSIC ASSIGN
PRESS FLEX(1 – 2)
Refer to Table 2.3.12.5-1
DISPLAY
Table 2.3.12.5-1 RSGM MUSIC ASSIGNMENTS (PGM 434)
Button
DISPLAY
1
001-001 MOH TYPE (0-1)
MUSIC 1 (1)
2
001-001 INT/EXT1 MUSIC
(0:INT/1:EXT1) : INT
This parameter establishes the contact state
that will activate the Alarm, close or open.
The contact can be treated to function as a
doorbell instead of an alarm.
The assigned stations will receive a Repeating
signal or single burst (ONCE) as the alarm
tone.
1.
Press the [PGM] button and dial 434.
2.
Use the dial-pad to enter the RSGM device number (001~025 for the IPECS-
50, 01~35 for the MFIM100, 001~150 for the MFIM300 or 001~300 for the
MFIM600).
3.
Press Flex button 1~2 for the desired setting, refer to Table 2.3.12.5-1.
4.
Use the dial pad to enter the required data, refer to Table 2.3.12.5-1.
5.
Press the [SAVE] button to save any changes.
REMARK
Assigns the source for MOH.
Assigns the input for source 1 (Internal or
External). This is the source for BGM/MOH
'Music'.
2-136
Issue 5.0
0: Open
CLOSE
1: Close
0: Door
ALARM
1: Alarm
0: Once
RPT
1: Repeat
RANGE
DEFAULT
0: Hold Tone
Music
1: Music
0: Internal
Internal
1: External 1