SOURce
n
:CURRent[:LEVel][:IMMediate][:AMPLitude]
Parameters
Comments
Chapter 3
n
SOURce
:CURRent[:LEVel][:IMMediate][:AMPLitude] <
immediately outputs the current set in value at channel n when the output relay is closed.
Parameter
Parameter
Name
n
keyword
SOURce
value
numeric (float 32) or
<
>
discrete
•
In the keyword,
SOURce
1 to 8 for
E1418A, E1418A Option 002
1 to 16 for
E1418A Option 001, E1418A Option 003.
Values of n outside these ranges will generate an error.
•
The
value
parameter is a floating point 32-bit number in the range of -0.02 A
<
>
to +0.02 A.
sets -0.02 Amps.
MIN
sets +0.02 Amps.
MAX
sets 0 Amps.
DEF
•
This command immediately programs the specified current on channel n. The
output state of the channel must be enabled for the current to appear at the output
terminals.
•
If the channel is in the voltage mode when this command is received, an error is
generated.
•
Related Commands:
SOURce
n
:FUNCtion:MODE CURRent
Type
-0.02 Amps to +0.02 Amps or
MIN | MAX | DEF
n, the valid range of n is:
SOURce
n
:CURRent[:LEVel][:IMMediate][:AMPLitude]?
,
OUTPut
HP E1418A SCPI Command Reference
SOURce
value
| MIN | MAX | DEF>
Range of
Values
1 to 8 or 1 to 16
n
[:STATe]
Default
1
0
,