Calibrationn:configure:voltage - HP E1418A User Manual

8/16-channel d/a converter module
Hide thumbs Also See for E1418A:
Table of Contents

Advertisement

CALibration
CALibration
n
:CONFigure:VOLTage?
Parameters
Comments
71
HP E1418A SCPI Command Reference
n
CALibration
:CONFigure:VOLTage?
calibration and returns a
Parameter
Parameter
Name
keyword
CALibration
n
Returns: an unsigned 16-bit integer (uint16).
In the keyword,
CALibration
1 to 8 for
E1418A, E1418A Option 002
1 to 16 for
E1418A Option 001, E1418A Option 003.
Values of n outside these ranges will generate an error.
This command is used together with the
perform voltage mode calibration.
The calibration is performed either at the CAL output terminals or at an individual
channel. The choice is made using the
command.
When the
DIAG:CAL:OUTP:MODE CALBus
is used, the output relay routes the calibration voltage to the CAL output
terminals (and opens all channel output terminals).
When the command
relay routes the calibration voltage to the channel terminals (the CAL terminals
are not connected).
The
DIAGnostic:CALibration:OUTPut[:MODE]
module before the
CALibration
This query will generate an error if the trigger system is waiting for a trigger event
when this command is received.
This query returns a
0
and a
1
to indicate the channel is ready for calibration.
This command is affected by the state of the program jumper for this channel on
the terminal module. To use this command:
the P/J jumper must be set to program selectable or, if set to jumper selectable,
the V/I jumper must be set to the voltage mode.
The jumpers are described on page 31.
Refer to Appendix D, "Voltage/Current Output Adjustment", starting on page 157,
for additional information about this command.
Related Commands:
DIAGnostic:CALibration:OUTPut[:MODE]
configures the channel for voltage mode
0
or
1
to indicate the channel's readiness for calibration.
Type
1
n, the valid range of n is:
CALibration
DIAGnostic:CALibration:OUTPut[:MODE]
DIAG:CAL:OUTP:MODE CHANnel
n
:CONFigure:VOLTage?
to indicate that the channel is not ready for calibration,
n
CALibration
:VALue:VOLTage?
Range of
Values
1 to 8 or 1 to 16
= ready,
0
= not ready.
n
:VALue:VOLTage?
command (also the reset state)
is used, the output
command must be sent to the
query.
,
Chapter 3
Default
1
query to