Diagnostic:calibration:output[:Mode]; Diagnostic:configure - HP E1418A User Manual

8/16-channel d/a converter module
Hide thumbs Also See for E1418A:
Table of Contents

Advertisement

DIAGnostic:CALibration:OUTPut[:MODE]?

Parameters
Comments

DIAGnostic:CONFigure?

Parameters
Comments
Chapter 3
DIAGnostic:CALibration:OUTPut[:MODE]?
for the module.
Returns: string.
The returned string will be one of
DIAGnostic:CONFigure?
the module.
Returns: six unsigned 16-bit integers (uint16).
This query returns six 16-bit words with the following meanings:
Integer
Returned
1st
2nd
3rd
A bit set to 1 indicates a non-isolated channel or no plug-on module
installed (DO NOT operate the module without a plug-on module).
4th
5th
6th
* For 8 channel configurations, the upper 8 bits of integers 3, 4, 5, and 6 are set to 1's.
queries the voltage calibration path
CALB
or
CHAN
returns six 16-bit words indicating the present settings of
Meaning
Expansion Board ID in the form: 0 = present, 7 = none
(expansion board contains channels 9–16).
Terminal Module ID in the form:
0 = screw type, 7 = none or other.
Isolated/Non-Isolated Channel Status
A bit set to 0 indicates an isolated channel.
Bits 0–15 correspond to channels 1–16, respectively*.
Channel Mode
A bit set to 0 indicates a current output channel.
A bit set to 1 indicates a voltage output channel.
Bits 0–15 correspond to channels 1–16, respectively*.
Channel Output State
A bit set to 0 indicates the channel output relay is closed.
A bit set to 1 indicates the channel output relay is open.
Bits 0–15 correspond to channels 1–16, respectively*.
Channel Mode Programmable State (P/J Jumper)
A bit set to 0 indicates a channel is not programmable.
A bit set to 1 indicates a channel is programmable.
Bits 0–15 correspond to channels 1–16, respectively*.