Reset and Registers
Note
121
HP E1418A Register-Based Programming
Following power-on or a
following states:
The Manufacturer ID and Device ID Registers remain unaffected.
–
The Channel Mode Register (base + 1A
–
for all channels (FFFF
(described on page 31) if the P/J jumper is in the jumper selectable
position.
The Channel Program Jumper Register (base + 16
–
selectable for all channels (FFFF
(described on page 31).
The Channel Relay Control Register (base + 1C
–
channel relays (FFFF
The Isolation Status Register (base + 14
–
non-isolated configuration of each channel.
The Calibration Control Register (base +08
–
voltage with the cal mux disabled (2000
Channel Trigger Register (base + 18
–
module is a 16-channel configuration or FF00
configuration.
The upper 8-bits of all channel related registers are set to 1's (FF
8-channel configurations.
*RST
command, the registers are put into the
) is set to voltage output
16
) or is set to the state set by the V/I jumper
16
) or to the position of the P/J jumper
16
).
16
) reflects the isolated/
16
).
16
) is set to 0000
16
) is set to program
16
) is set to open all
16
) is set to calibrate
16
if the
16
if an 8-channel
16
) for
16
Appendix B