APPLy
n
:VOLTage
Parameters
Comments
Chapter 3
n
value
APPLy
:VOLTage <
channel, n.
Parameter
Parameter
Name
n
keyword
APPLy
value
numeric (float 32) or
<
>
discrete
In the keyword,
APPLy
1 to 8 for
E1418A, E1418A Option 002
1 to 16 for
E1418A Option 001, E1418A Option 003.
Values of n outside these ranges will generate an error.
The
value
parameter can range from -16 Volts to +16 Volts.
<
>
MIN
sets -16 Volts output.
sets +16 Volts output.
MAX
sets 0 Volts output.
DEF
This command is affected by the state of the program jumper on the terminal
module for this channel. To use the
the P/J jumper must be set to program selectable or, if set to jumper selectable,
the V/I jumper must be set to the voltage mode.
This jumper is described on page 31.
Equivalent Commands:
n
SOURce
:VOLTage[:LEVel][:IMMediate][:AMPLitude]
*RST Condition:
If the P/J jumper is set to program selectable:
output mode is set to voltage, 0 volts output, output relay open.
If the P/J jumper is set to jumper selectable:
output mode is set by the V/I jumper, 0 volts or amps, output relay open.
| MIN | MAX | DEF>
Type
-16 V to +16 V or MIN | MAX | DEF
n, the valid range of n is:
APPLy
n
:VOLT
SOURce
n
:FUNCtion:MODE VOLT
HP E1418A SCPI Command Reference
outputs a voltage on the specified
Range of
Values
1 to 8 or 1 to 16
command:
,
,
n
OUTPut
[:STATe] ON
APPLy
Default
1
0
64