2

General Informationon Destination 2.3 Insert (EB00021)

2.1 Appliance performance
Fuel type
Recommended heating area
Firebox volume
[*]
Maximum burn time
Maximum heat output (dry cordwood)
Overall heat output rate (min. to max.)
Average overall efficiency
Douglas Fir
Average overall efficiency
(2)(6)
Optimum efficiency
Average particulate emissions rate
(8)
Average CO
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss
factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the
manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a
power failure.
(1)
Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn
time and maximum heat output.
(2)
Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19%
and 25%.
(3)
As measured per CSA B415.1-10 stack loss method.
(4)
Higher Heating Value of the fuel.
(5)
Lower Heating Value of the fuel.
(6)
Optimum overall efficiency at a specific burn rate (LHV).
(7)
This appliance is officially tested and certified by an independent agency.
(8)
Carbon monoxide.
Destination 2.3 Insert Installation and Operation Manual
(1)
[*]
(2)(3)
(3)
- EPA Cribs /
(3)
- Dry cordwood
(7)
Dry cordwood
2
750 to 2,100 ft
(70 to 195 m
3
3
2.3 ft
(0.065 m
)
8 h
75,000 BTU/h (22.0 kW)
12,500 BTU/h to 31,300 BTU/h
(3.7 kW to 9.2 kW)
(4)
69.5% (HHV
)
(4)
To come% (HHV
)
77.2%
3.9 g/h (EPA / CSA B415.1-10)
137.4 g/h
2
)
(5)
75.2% (LHV
)
(5)
To come% (LHV
)
7

Advertisement