Appendix 2: Installing the Optional Fresh Air Intake Kit
(AC01298)
Note: Only remove the knock-out that will be connected to the fresh air inlet.
To install a fresh air intake kit to the insert, the purchase of accessory AC01298 is required.
46
Using pliers, remove the rectangular knock-out
plate (A) located on the left or right side of the
convection air jacket. Choose the side that is
best for your installation.
Then, install the fresh air kit adapter (B) using
4 screws (C). Secure the flexible pipe (E) (part
#AC02090 not supplied) to the adapter (B)
using one of the adjustable pipe clamps (D).
Secure the other end of the pipe to the outside
wall
termination
adjustable pipe clamp (D). The outside wall
termination (F) must be installed outside of the
building.