Enerzone Destination 2.3 Insert Installation And Operation Manual page 37

Table of Contents

Advertisement

CLEARANCES
F
16" (406 mm)
G
12" (305 mm)
H
20" (508 mm)
I
22" (559 mm)*
O
12" (305 mm)
P
1" (25 mm)
B
M
N
Minimum floor to ceiling clearance: 84'' (213 cm)
* For an 8" (203 mm) mantel shelf. See Section 8.3 Compliance of a Combustible Mantel
Shelf for other mantel shelf dimensions.
** Where a fresh air intake is needed, we suggest you add a minimum of 4" to the width of the
minimum masonry opening.
*** If projection kit AC01323 (sold separately) is used L = 17 5/8" or 15 5/8". If installed without
projection kit L = 19 5/8".
Note 1 From door opening. The depth of the hearth extension in front of the insert is included in
the calculation of the floor protector's dimensions. The masonry hearth should be at least 5" (127
mm) higher than the combustible floor in front of it and a floor protection must extend at least 16"
(406 mm USA) and 18" (457 mm Canada) with an R value of 1.24 or more. If the hearth elevation
is lower than 5" (127 mm), the non-combustible floor protector (B) in front of the insert should have
an R value equal or greater than 1.24 and should extend at least 20" (508 mm) in front of the unit.
Destination 2.3 Insert Installation and Operation Manual
FLOOR PROTECTION
CANADA
18" (457 mm) – Note1
8" (203 mm)
N/A (USA only)
MINIMUM MASONRY
OPENING
J
23 3/4" (603 mm)
K
28 7/8" (733 mm)**
L
19 5/8" (498 mm)***
USA
16" (406 mm) – Note 1
N/A (Canada only)
8" (203 mm)
37