Enerzone DESTINATION 1.9 Owner's Manual

Enerzone DESTINATION 1.9 Owner's Manual

Wood insert

Advertisement

Quick Links

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS
IN THE AREA.
READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD INSERT. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
READ AND KEEP THIS MANUAL FOR REFERENCE
Printed in Canada
DESTINATION 1.9
INSERT
(EB00066 Model)
Wood Insert
Owner's Manual
Part 2 of 2
INSTALLATION AND
OPERATION REQUIREMENTS
Safety tested according to
ULC S628, UL 1482 and
UL 737 by an accredited
US Environmental Protection
Agency phase II certified
wood insert compliant with
2020 cord wood standard.
laboratory.
EPA
< ≤
2.5
g/h
46279A

Advertisement

Table of Contents
loading

Summary of Contents for Enerzone DESTINATION 1.9

  • Page 1 Wood Insert Owner's Manual Part 2 of 2 INSTALLATION AND OPERATION REQUIREMENTS DESTINATION 1.9 INSERT (EB00066 Model) Safety tested according to ULC S628, UL 1482 and UL 737 by an accredited laboratory. US Environmental Protection Agency phase II certified wood insert compliant with 2020 cord wood standard.
  • Page 2 It is also highly recommended to register the warranty online at https://www.enerzone-intl.com/en/warranty/warranty-registration/ Registering the warranty will help to quickly find the information needed on the unit.
  • Page 3 CERTIFICATION PLATE...
  • Page 5: Table Of Contents

    Optional Fresh Air Intake Kit Installation...............28 3.10 Optional Fire Screen Installation ..................29 3.11 Air Tubes and Baffle Installation ..................30 3.12 Removal Instructions ....................33 3.13 Exploded Diagram and Parts List ................34 4. ENERZONE LIMITED LIFETIME WARRANTY ..............37 Product Specification Manual - Destination 1.9 Page 5...
  • Page 6: General Information

    This appliance is officially tested and certified by an independent agency. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and draft ASTM WK47329-14 based on the ATM send by EPA on October 12th, 2017. Carbon monoxide. Page 6 Product Specification Manual - Destination 1.9...
  • Page 7: Specifications

    CAN/CSAZ240 MH standard. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and draft ASTM WK47329-14 based on the ATM send by EPA on October 12th, 2017. Product Specification Manual - Destination 1.9 Page 7...
  • Page 8: Dimensions

    Figure 1 : Top View Figure 2 : Side View 21" 533mm 15 1/4" 388mm 36" 914mm 8 1/8" 206mm 18" 457mm 10 1/2" 2 1/4" 265mm 57mm Figure 3 : Front View Page 8 Product Specification Manual - Destination 1.9...
  • Page 9 3/16" 16 3/4" 426mm 19 1/4" 490mm 12 3/8" 315mm 19 1/4" 490mm 12 3/8" 315mm Figure 5 : Top View - Combustion Chamber Figure 6 : Side View - Combustion Chamber Product Specification Manual - Destination 1.9 Page 9...
  • Page 10: Epa Loading

    OFF to avoid blowing ash outside the combustion chamber. Refer to section "5.1 Blower" of the owner's manual for how to turn OFF the fan. Page 10 Product Specification Manual - Destination 1.9...
  • Page 11: Clearances To Combustible Material

    1" (25 mm) 15 ½" (394 mm) surround If a fresh air intake is required, it is recommended to add at least 4" to the width of the minimum opening of the hearth. Product Specification Manual - Destination 1.9 Page 11...
  • Page 12: Floor Protection

    (0 mm) D=B- G (257 mm) extension facing From door opening. The depth of the hearth extension in front of the insert is included in the calculation of the floor protector’s dimensions. Page 12 Product Specification Manual - Destination 1.9...
  • Page 13: R Value

    Four inches of brick (R = 4 x 0,2 = 0,8) plus 1 inch of Durock® (R = 1 x 0.52 = 0.52). 0.8 + 0.52 = 1.32. Information as reported by manufacturers and other resources. Horizontal still air can’t be «stack» to accumulate R-values; each layer must be separated with another non-combustible material. Product Specification Manual - Destination 1.9 Page 13...
  • Page 14 K values to R by dividing the thickness of each material by its K value. Add R values of the proposed materials as shown in the previous example. Exemple: K value = 0.75 Thickness = 1 R value = Thickness/K = 1/0.75 = 1.33 Page 14 Product Specification Manual - Destination 1.9...
  • Page 15: Installing Options On Your Product And Replacing Parts

    Remove the split pin by pulling and turning it using pliers. Turn the handle one counterclockwise turn to increase pressure. Reinstall the split pin with a small hammer. Figure 11 : Removing the split pin Figure 12 : Installing the split pin Product Specification Manual - Destination 1.9 Page 15...
  • Page 16 Using a flat screwdriver, turn the adjustable hinge rods in the direction shown to adjust the doors. Tighten all door hinge pressure screws when they are at the desired positions. Configurations 1-2-3-4-5-6, show in which direction these act on the adjustment of the door. Page 16 Product Specification Manual - Destination 1.9...
  • Page 17: Removal Of Refractory Stones

    Note: The images shown are for guidance only and may be different from your product, but the assembly remains the same. • Empty the combustion chamber. Figure 13 : Empty the combustion chamber Product Specification Manual - Destination 1.9 Page 17...
  • Page 18: Connecting The Blower With A Bx Wire

    (B) and gain access to the wires. Save the screws for later. 2. Disconnect the black (C) and white (D) wires. 3. Remove the ground screw (E) to remove the green wire. Save the screw for later. Page 18 Product Specification Manual - Destination 1.9...
  • Page 19 5. Remove the piece of metal (G) from the plate (B) obstructing the hole to the left of the power cord (H) using pliers or a screwdriver. Cut the power cord (H) on each side of the black clamp. Product Specification Manual - Destination 1.9 Page 19...
  • Page 20 9. Close the connection box by screwing in the plate (B) with the two screws (A) kept in step 1 and secure the BX wire by tightening the screw (L) of the connector (I). Page 20 Product Specification Manual - Destination 1.9...
  • Page 21: Changing The Side Of The Blower Power Cord

    Remove the four screws (F) that hold the connection box (G) to the insert and gently pull it out until the white and black wires come out of the insert. Keep the screws. Product Specification Manual - Destination 1.9 Page 21...
  • Page 22 Then pass the wires through the grommet (J) located on the side at the front of the device. 5. Screw the connection box (G) with the four screws (F) kept in step 2. Page 22 Product Specification Manual - Destination 1.9...
  • Page 23 (extension supplied with the manual kit). 8. Secure the excess wires using the three plastic grommets (C) removed in step 1. 9. Reinstall the grille (B) with the screws (A) kept in step 1. Product Specification Manual - Destination 1.9 Page 23...
  • Page 24: Blower Removal

    (B). of the grille (B) to be able to remove it. 3. Unscrew the two wing nuts (C) on each 4. Take out the fan (D). side of the fan. Page 24 Product Specification Manual - Destination 1.9...
  • Page 25: Removable Air Control Handle

    This insert comes with a removable handle for the primary air control. A holder for the handle is supplied with the manual. Here is an example of the holder installation. CAUTION: Do not leave the handle on the air control after use, as it will get very hot. Product Specification Manual - Destination 1.9 Page 25...
  • Page 26: Faceplate Removal

    It is not necessary to keep the screws (A), since they were only useful for the transport of the insert. COMMENT ENLEVER LA FAÇADE (LE PRODUIT ARRIVE AVEC LA FAÇADE INSTALLÉES) 3/8" Page 26 Product Specification Manual - Destination 1.9...
  • Page 27: Faceplate Decorative Panel Installation/Removal

    SI LE CLIENT VEUT INSTALLER SONT PRODUIT AVEC L'ENTONNOIR IL FAUT QU'IL INSTALLE LE RESTANT DES VIS (6X) DETAIL I Faceplate decorative panel installation • Screw the panel with 6 additional screws (B). Product Specification Manual - Destination 1.9 Page 27...
  • Page 28: Optional Fresh Air Intake Kit Installation

    (J) using the other pipe clamp. The outside wall termination must be installed outside of the home. The pipe must be HVAC type, insulated, and must comply with ULC S110 and/or UL 181, Class 0 or Class 1. Page 28 Product Specification Manual - Destination 1.9...
  • Page 29: Optional Fire Screen Installation

    In the United States or in provinces with a particulate emissions limit (e.g.: US EPA), the use of open-door wood stoves with a rigid firescreen is prohibited. Open the door. Hold the fire screen by the two handles and bring it close to the door opening. Product Specification Manual - Destination 1.9 Page 29...
  • Page 30: Air Tubes And Baffle Installation

    Starting with the rear tube, lean and insert the right end of the secondary air tube into the rear right channel hole. Then lift and insert the left end of the tube into the rear left channel. Page 30 Product Specification Manual - Destination 1.9...
  • Page 31 To remove the tubes use the above steps in reverse order. Note that secondary air tubes (A) can be replaced without removing the baffle board (B) and that all tubes are identical. Product Specification Manual - Destination 1.9 Page 31...
  • Page 32 Page 32 Product Specification Manual - Destination 1.9...
  • Page 33: Removal Instructions

    • Remove faceplate (D) by lifting it and then pulling on it. • Remove the three screws securing the pipe connector (A). • Unscrew the bolts securing the insert to the floor on each side of the unit (B). Product Specification Manual - Destination 1.9 Page 33...
  • Page 34: Exploded Diagram And Parts List

    3.13 Exploded Diagram and Parts List Page 34 Product Specification Manual - Destination 1.9...
  • Page 35 STAINLESS WASHER ID 17/64" X OD 1/2" 30025 1/4-20 X 1/2" PAN-HEAD QUADREX BLACK SCREW SE72072 REPLACEMENT HANDLE WITH LATCH KIT AC09185 DOOR LATCH KIT PL74795 DECORATIVE DOOR PLATE AC01298 5"Ø FRESH AIR INTAKE KIT Product Specification Manual - Destination 1.9 Page 35...
  • Page 36 30337 SQUARE HEAD SET SCREW 1/2-13 X 1-3/4" SE24367 DESTINATION 1.9 FACEPLATE ASSEMBLY PL74844 DESTINATION 1.9 GRILL SE46279 DESTINATION 1.9(EB00066) MANUAL KIT AC05959 METALLIC BLACK STOVE PAINT - 342 g (12oz) AEROSOL Page 36 Product Specification Manual - Destination 1.9...
  • Page 37: Enerzone Limited Lifetime Warranty

    Labour cost and repair work to the account of the manufacturer are based on a predetermined rate schedule and must not exceed the wholesale price of the replacement part. Shall your unit or a components be defective, contact immediately your ENERZONE dealer. To accelerate processing of your warranty claim, make sure to have on hand the following information when calling: •...
  • Page 38 Resale is strictly prohibited. The manufacturer may update St-Augustin-de-Desmaures (Québec) Canada this document from time to time and cannot be responsible G3A 2H3 for problems, injuries, or damages arising out of the use 418-908-8002 of information contained in any document obtained from https://www.enerzone-intl.com/en/ unauthorized sources. tech@sbi-international.com...

This manual is also suitable for:

Eb00066

Table of Contents