1 Safety Information

1.1 Summary of Operation and Maintenance Cautions and Warnings

OPERATE ONLY WITH DOOR FULLY CLOSED OR FULLY OPEN WITH FIRE SCREEN IN PLACE.
IF DOOR IS LEFT PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT OF THE OPENING,
CREATING RISKS FROM BOTH FIRE AND SMOKE.
HOT WHILE IN OPERATION, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT
MAY CAUSE SKIN BURNS. GLOVES MAY BE NEEDED FOR INSERT OPERATION.
USING AN INSERT WITH CRACKED OR BROKEN COMPONENTS, SUCH AS GLASS OR
FIREBRICKS OR BAFFLES MAY PRODUCE AN UNSAFE CONDITION AND MAY DAMAGE THE
INSERT.
OPEN THE AIR CONTROL FULLY BEFORE OPENING THE LOADING DOOR.
THIS INSERT HAS BEEN TESTED FOR USE WITH AN OPEN DOOR IN CONJUNCTION WITH A
FIRE SCREEN (AC01315, SOLD SEPARATELY). THE DOOR MAY BE OPEN OR FIRE SCREEN
REMOVED ONLY DURING LIGHTING PROCEDURES OR RELOADING. ALWAYS CLOSE THE
DOOR OR PUT BACK THE FIRE SCREEN AFTER IGNITION. DO NOT LEAVE THE INSERT
UNATTENDED WHEN THE DOOR IS OPENED WITH OR WITHOUT FIRE SCREEN.
NEVER USE GASOLINE, LANTERN FUEL (NAPHTHA), FUEL OIL, MOTOR OIL, KEROSENE,
CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS OR AEROSOLS TO START A FIRE IN THIS
INSERT. KEEP ALL SUCH LIQUIDS OR AEROSOLS WELL AWAY FROM THE INSERT WHILE IT IS
IN USE.
DO NOT STORE FUEL WITHIN HEATER MINIMUM INSTALLATION CLEARANCES.
BURN ONLY SEASONED NATURAL FIREWOOD.
DO NOT BURN:
GARBAGE OF ANY KIND,
o
COAL OR CHARCOAL,
o
TREATED, PAINTED OR COATED WOOD,
o
PLYWOOD OR PARTICLE BOARD,
o
FINE PAPER, COLORED PAPER OR CARDBOARD,
o
SALT WATER DRIFTWOOD,
o
MANUFACTURED LOGS CONTAINING WAX OR CHEMICAL ADDITIVES,
o
RAILROAD TIES OR
o
LIQUIDS SUCH AS KEROSCENE OR DIESEL FUEL TO START A FIRE.
o
THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE
WITH THESE INSTRUCTIONS.
DO NOT ELEVATE THE FIRE BY MEANS OF GRATES, AND IRONS OR OTHER MEANS.
SOME JURISDICTIONS IN THE USA REQUIRE A SUPPLY OF OUTDOOR COMBUSTION AIR FOR
THE INSERT. IN CANADA, AN OUTDOOR AIR SUPPLY IS NOT REQUIRED, IF A CARBON
MONOXIDE (CO) DETECTOR/ALARM IS LOCATED IN THE ROOM IN WHICH THE INSERT IS
INSTALLED. THE CO DETECTOR WILL PROVIDE WARNING IF FOR ANY REASON THE WOOD
INSERT FAILS TO FUNCTION CORRECTLY. IF YOU ARE REQUIRED TO INSTALL AN OUTDOOR
AIR SUPPLY, WE RECOMMEND THAT YOU ALSO INSTALL A CO DETECTOR/ALARM TO
PROVIDE WARNING IF SMOKE SPILLAGE FROM THE INSERT OCCURS.