SurroundVideo®
O mni
G 2
OUTPUT Relay Control and Function
The camera has an output for activating an external device. The camera supports both transient and
continuous relay operation. You can operate the relay during an active connection using the API
command set. Typical applications include turning on lights or activating doors and locks.
Figure 3: Relay wiring with power source to the camera
Camera output can be turned on|off with the following command:
http://camera_ip/set?auxout=("on"|"off")
The following table shows the output control and electrical characteristics:
Terminals
OUT+ &
OUT-
Page | 30
support@arecontvision.com
+1.818.937.0700
877.CAMERA.8
Output Control
External
Camera
Status
Status
OPEN
OFF
CLOSED
ON
www.arecontvision.com
avsales@arecontvision.com
+
0-‐120VDC
100mA
-‐
(max)
Max
Max
Voltage
Current
120V
-
100mA
Installation
M anual
-
Need help?
Do you have a question about the AV12275DN-NL and is the answer not in the manual?