Codabar
•
Check character must be included in label data.
•
Label length including check character and excluding prefix character must meet requirements imposed by
the main scanner's fixed or variable label length control for this symbology type.
•
Prefix must be an ASCII character '%'.
•
Start stop character sets must meet the matching requirement set forth by the scanner configuration item
Start/Stop Character Match
•
Start stop character sets must be of the form ABCD/ABCD and must be included in the label.
•
Example: '%s$99.95s' (the lower case 's' at each end of the example is a placeholder for the start stop charac-
ter set).
Code 128
•
Prefix must be an ASCII character '#'.
•
Label length excluding prefix character or function code 3 for Code 128 programming labels must meet
requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Function characters may be transmitted as a hexadecimal value 8x. Where x correlates to function characters
1 thru 4 as follows:
•
x80 = function code 1
•
x81 = function code 2
•
x82 = function code 3
•
x83 = function code 4
•
For Code 128 programming labels the format is of the general form '#/82nnnnn/r ' - /82 is hexadecimal 82
and /r is carriage return.
•
Example: '#Code_128.Test'.
Product Reference Guide
.
193