Codabar

Check character must be included in label data.
Label length including check character and excluding prefix characters must meet requirements imposed by
the main scanner's fixed or variable label length control for this symbology type.
Prefix must be ASCII characters ']F0'.
Start stop character sets must meet the matching requirement set forth by the scanner configuration item
Start/Stop Character Match
Start stop character sets s must be of the form ABCD/ABCD and must be included in the label.
Example: ']F0s$99.95s' (the lower case 's' at each end of the example is a placeholder for the start stop charac-
ter set).

MSI

Check character must be included in label data.
Label length including check character and excluding prefix characters must meet requirements imposed by
the main scanner's fixed or variable label length control for this symbology type.
Prefix must be ASCII characters ']M0'.
Example: ']M0144769254'.

Code 93

Prefix must be ASCII characters ']G0'.
Label length excluding prefix characters must meet requirements imposed by the main scanner's fixed or vari-
able label length control for this symbology type.
Example : ']G0Code93-test'.
RSS-14
Prefix must be ASCII characters ']e0'.
Check character must be included in label.
Label length excluding prefix characters must be 14 characters.
Example: ']e001044123456789'.

RSS Expanded

Prefix must be ASCII characters ']e0'.
Label length excluding prefix characters must be at least 1 character. Maximum length is the maximum label
size supported by the scanner.
Example: ']e001900123456789083103001750'.