[6] CHECK POINTS OF EVERY 1000 HOURS

Checking Radiator Hoses and Clamp Bands
1. Check to see if the radiator hoses are properly fixed every 200
hours of operation or every six months, whichever comes first.
2. If the clamp is loose, apply oil to the threads and retighten it
securely.
3. The coolant hose is made of rubber and tends to age. It must be
replaced every two years. Also replace the clamp and tighten it
securely.
(1) Upper Hose
Checking PCV Valve
1. Disconnect the breather hose (3) from the intake manifold (1).
2. Blow into the breather hose (3).
3. Stop to blow.
4. Make sure that a slight operation sound is heard from the PCV
valve.
5. If there is no operation sound, replace the PCV valve (2).
6. Connect the breather hose (3) to the intake manifold (1)
(1) Intake Manifold
(2) PCV Valve
Checking Coolant Hose of LPG Vaporizer
1. Check the coolant hoses (1) for damage.
2. If the coolant hose is damaged, replace it.
(1) Coolant Hose
Checking LPG Lock Off Valve
1. Start the engine.
2. Make sure that an operation sound of solenoid is heard from the
LPG lock off valve.
3. Make sure that there is no fuel leakage from the LPG lock off
valve.
4. If there is no operation sound or fuel leakage, replace the LPG
lock off valve.
G-15
GENERAL
(2) Lower Hose
9Y1210571GEG0039US0
(3) Breather Hose
9Y1210661GEG0039US0
(2) LPG Tank
9Y1210661GEG0019US0
9Y1210661GEG0040US0