WG1605-G-E3,WG1605-L-E3,WG1605-GL-E3, WSM
Resistance of Fuel Pressure Manifold (FPM)
1. Disconnect the connector.
2. Measure the resistance between terminal 1 and terminal 2 with
an ohmmeter.
3. If the resistance is not with in the factory specifications, replace
it.
Factory
Resistance
specifica-
tion
(1) Terminal 1
(2) Terminal 2
Injector
1. Disconnect the connector.
2. Measure the resistance between terminals with an ohmmeter.
3. If the resistance is not with in the factory specifications, replace
it.
Resistance
Factory specification
1-S17
Terminal 1 –
2.35 to 2.65 kΩ
Terminal 2
at 20 °C (68 °F)
(3) Terminal 3
(4) Terminal 4
9Y1210661ENS0093US0
11.7 to 12.3 Ω
at 20 °C (68 °F)
9Y1210661ENS0094US0
KiSC issued 01, 2012 A