WG1605-G-E3,WG1605-L-E3,WG1605-GL-E3, WSM

[9] CHECK POINTS OF EVERY 2 YEARS

Replacing Intake Air Line
1. Replace the intake hose and the clamps between the air cleaner
and the electronic throttle body or gas mixer.
Replacing Breather Hose
1. Replace the breather hose and the clamps between the head
cover and the intake manifold.
(1) Breather Hose
Replacing LPG Fuel Hose and Clamp Bands
(WG1605-L-E3, WG1605-GL-E3)
1. Replace the fuel hose and the clamps.
Replacing Coolant Hose of LPG Vaporizer
(WG1605-L-E3, WG1605-GL-E3)
1. Connect the new coolant hose (1) and (2) to the vaporizer (3).
2. The coolant replenished to radiator, and bleed the air from the
vaporizer (3).
(1) Coolant Hose
(2) Coolant Hose
Checking LPG Vaporizer (WG1605-L-E3, WG1605-GL-E3)
1. Make sure that any fuel leaks at the inlet and outlet fittings.
2. Make sure that the mounting bracket to insure the vaporizer is
securely mounted.
Replacing Radiator Hoses and Clamp Bands
CAUTION
• Do not remove the radiator cap when the engine is hot.
Then loosen cap slightly to the stop to relieve any excess
pressure before removing cap completely.
1. Drain the coolant.
2. Loosen the clamp bands.
3. Remove the upper hose (1) and lower hose (2).
4. Replace new upper / lower hose (1), (2) and clamp bands.
5. Tighten the clamp bands.
6. Fill with clean water and anti-freeze until the coolant level is just
below the port. Install the radiator cap securely.
(1) Upper Hose
G-20
GENERAL
9Y1210661GEG0047US0
9Y1210661GEG0048US0
9Y1210661GEG0025US0
(3) Vaporizer
(4) LPG Tank
9Y1210661GEG0026US0
9Y1210661GEG0041US0
(2) Lower Hose
9Y1210571GEG0042US0
KiSC issued 01, 2012 A