Mantel Requirements

If installing a TV above a mantel, see the section "Televisions Placed Above the Fireplace" on page 10.
Use the table below to determine the maximum mantel depth allowed. The mantel depth (measured from the
non-combustible facing) must fall within the shaded portion of the table.
Any material above the fireplace that protrudes more than 3/4" (19mm) from the non-combustible facing is
considered a mantel and must meet the mantel requirements.
47" (1194mm)
46" (1169mm)
45" (1143mm)
Mantel
44" (1118mm)
Height
43" (1093mm)
Above
42" (1067mm)
Base (a)
41" (1042mm)
40" (1016mm)
39" (991mm)
38" (966mm)
37 (940mm)

Mantel Column Clearances

Combustible mantel columns (legs) that protrude more than ¾" (19mm) from the front of the fireplace
require a 3" (77mm) clearance to the side of the fireplace.
Combustible mantel columns (legs) that protrude ¾" (19mm) or less from the glass frame must meet the
facing clearances (minimum 0" (0mm) from the side of the fireplace).
Non-combustible mantel columns do not have a minimum clearance.
© Travis Industries
Installation
(for qualified installers only)
Maximum Mantel Depth (b)
b
a