Vent Configuration: Horizontal Termination With Vertical Rise - Travis Industries 4415 HO ST Installation Manual

With screen
Hide thumbs Also See for 4415 HO ST:
Table of Contents

Advertisement

Vent Configuration: Horizontal Termination with Vertical Rise

 Use 4x6-5/8" Diameter Coaxial Vent. Connect a 8" to 6-5/8" reducer directly to the
fireplace (sku 98900165).
 NOTE: The included pipe shield is not required and may be discarded. The included
firestops may be discarded.
 The termination must fall within the shaded area shown in the chart. Use the indicated
restrictor positions.
 Up to 3 elbows (45° or 90°) may be used. Only one horizontal elbow may be used.
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
© Travis Industries
Installation
Intake Restrictor # 1 (stock)
Exhaust Restrictor # 0 (removed)
Diffuser Closed (stock)
Attach reducer directly to the fireplace.
(for qualified installers only)
Intake Restrictor # 1 (stock)
Exhaust Restrictor # 1 for NG
Exhaust Restrictor # 0 for LP (removed)
Diffuser Closed (stock)
H2
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
This is considered a
vertical elbow
4150624
29
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
100-01425