34
Facing Requirements – Extended (Tile Over) Install
The included fiber board is required and must remain attached to the fireplace (see "a" below).
Drywall (or other combustible) may be placed above the fiber board (see "b" below) and to the sides and
below the face of the fireplace. Secure the drywall to the vertical drywall supports. Do not place drywall
over the front of the fireplace.
Tile or other non-combustible facing may be placed along the front of the fireplace around the perimeter of the
glass opening (see "c" below). Typical installations use 12" (305mm) or greater of non-combustible facing
around the perimeter of the glass opening. Do not install facing over the ledge to the glass opening.
WARNING: Do not use adhesive to secure the facing. The high temperatures of the
fireplace may cause adhesives to emit odors. Use mastic or thin set (or other non-
combustible, non-odorous adherent) to attach the facing.
NOTE: Screws may be used to secure cement board or tile backer to the fireplace. Do not
penetrate the fireplace more than 1/2" (13mm).
© Travis Industries
Installation
(for qualified installers only)
b
c
45-1/4"
1150mm
a
4140627
(a) Fiber Board
(included with
fireplace)
(b) Drywall (or other
11-1/4"
combustible)
286mm
(c) Tile (or other
non-
15-3/4"
combustible)
401mm
10-3/8"
264mm
100-01353