Mantel Requirements
•
The illustration below details mantel clearances and maximum mantel depth.
•
Any combustible facing material that protrudes more than 20mm from the face of the fireplace is
considered a mantel and must meet the mantel requirements.
Mantel (combustilbe or non-combustible)
980mm
38-1/2"
Travis Industries
Installation
305mm
12"
Maximum
Maximum
(for qualified installers only)
Combustible mantel columns (legs) that
Combustible mantel column (legs) that
protrude more than 3/4" from the glass
protrude more than 20mm from the glass
frame must meet the sidewall clearance (1").
frame must meet the sidewall clearance
If they protrude 3/4" or less, they may be
(25mm). If they produce 20mm or less, they
placed directly to the side (but not in front) of
may be place directly to the side (but not in
the fireplace.
front) of the fireplace
Non-combustible mantel columns do not
Non-combustible mantel columns do not
have a minimum clearance.
have a minimum clearance.