Minimum Vent Configuration

 Use 5x8" Diameter Coaxial Vent
 NOTE: Use the included pipe shield and both 8" firestops (use on front and back of wall
penetration).
 The termination must fall within the shaded area shown in the chart. Use the indicated
restrictor positions.
 One 45° elbow may be used on the horizontal run.
 HINT: Use minimum vent kit "H" from Travis Industries (additional vent will be required).
NG (Natural Gas)
12" (305mm) Section
LP (Propane)
12" (305mm) Section
© Travis Industries
Installation
(for qualified installers only)
3 feet (0.915m)
0 feet
3 feet (0.915m)
0 feet
Exhaust Restrictor # 1 (stock)
Diffuser Closed (stock)
Intake Restrictor # 1 (stock)
Min. 24" (600mm) Horizontal Section
Max. 18' (5.5M) Horizontal Section(s)
Exhaust Restrictor # 0 (removed)
Diffuser Closed (stock)
Intake Restrictor # 1 (stock)
Min. 24" (600mm) Horizontal Section
Max. 14' (4.2M) Horizontal Section(s)
4150624
27
100-01425